Commissioning Your 1394 Analog Servo System
Defining Limits
This procedure assumes that you have wired your 1394 Analog Servo
System and have completed the procedures in the following sections
of this chapter:
•
Removing and Re-Applying Power
•
Setting Up at the System Level
•
Setting Up Analog Test Points
•
Defining Your Motors
•
Defining a Reference Source for Your Axes
To define limits:
1.
When the
Ax: Current Limit
message appears, press
SEL
. The
cursor moves to the bottom line.
2.
Press either the up or down arrow until the appropriate current
limit appears.
3.
Default values are set by the motor type you selected. You cannot
exceed this value.
4.
Press
ENTER
. The system records your choice and the cursor
moves to the top line.
5.
Press
ENTER
. A message similar to the following appears:
Note: Default values are set by the motor type you
selected. You cannot exceed this value.
6.
Press
SEL
. The cursor moves to the bottom line.
7.
Press either the up or down arrow until the appropriate velocity
limit appears.
8.
Press
ENTER
. The system records your choice and the cursor
moves to the top line.
9.
Press
ENTER
. A message similar to the following appears:
10.
Go to
Auto Tuning
.
Ax:Vel Lim
5000.0 rpm
Ax:ATune Select
Idle
Содержание 1394 SERCOS
Страница 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Страница 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Страница 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Страница 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Страница 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Страница 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Страница 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...
Страница 300: ...I 8 Index Publication 1394 5 0 May 2000...