Publication 1394-5.0 — May 2000
8-26
Configuring Your 1394 Analog Servo System
[Enble Input Mode]
This parameter specifies whether the hardware
enable signals are used on the wiring board for
input. If configured as Not Used, the HIM or
SCANport device will provide the enable signal
for the axis.
Parameter Numbers
24
Parameter Group
Setup
Display Units
None
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Default Value
0
"Used"
Selections
0
"Used"
1
"Not Used"
[Vel Command]
Present velocity command for the axis (after all
limiting has occurred).
Parameter Numbers
220, 221, 222, 223
Parameter Group
Monitor Parms, Vel Cmd Data
Display Units
rpm
Parameter Type
Read Only
Linkable
No
[Vel Damp Sel]
This parameter is associated with the auto tune
function and specifies the velocity damping
desired by the user. The auto tuning procedure
calculates a new set of Velocity Loop Gains and
a new Current Rate Limit when the user initiates
the Auto Tune Calculate function.
Parameter Numbers
256, 257, 258, 259
Parameter Group
ATune Config
Display Units
None
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Default Value
0
"Zeta=0.87"
Selections
0
"Zeta=0.87"
Underdamped
1
"Zeta=1.00"
Critically Damped
2
"Zeta=0.70"
Underdamped
3
"Zeta=1.40"
Overdamped
[Vel Feedback]
Present velocity feedback for the axis (after all
filtering has occurred).
Parameter Numbers
224, 225, 226, 227
Parameter Group
Monitor Parms, Vel Cmd Data
Display Units
rpm
Parameter Type
Read Only
Linkable
No
[Vel Lim]
This parameter automatically changes both
[CW/CCW Vel Lim] to the same value. (for
convenience during commissioning).
Parameter Numbers
120, 121, 122, 123
Parameter Group
Velocity Cmd Data
Display Units
rpm
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Minimum Value
0.0 rpm
Maximum Value
8000.0 rpm
Default Value
This is determined by the motor catalog number.
[Vel LowPas BW]
Specifies the single pole low pass velocity
feedback filter bandwidth. A value of 0 disables
the filter.
Parameter Numbers
140, 141, 142, 143
Parameter Group
Vel Loop Tune
Display Units
Hz
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Minimum Value
0 Hz
Maximum Value
1500 Hz
Default Value
0 Hz
Содержание 1394 SERCOS
Страница 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Страница 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Страница 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Страница 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Страница 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Страница 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Страница 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...
Страница 300: ...I 8 Index Publication 1394 5 0 May 2000...