background image

 

GLD

 Touch Screen Reference V1.2 – Issue 1                               16

 

        

ALLEN

&

HEATH

 

3.17

 

Routing page – DCA Master 

GLD provides 16 DCA Groups. These can be used as DCA 
Groups (level control) or Mute Groups (mute masters). 
 
The following can be assigned to DCA Groups: 

 

Input channels 

 

FX returns 

 

FX sends 

 

Group masters 

 

Aux masters 

 

Matrix masters 

 

Main LR master 

 

 

 
There are two ways to assign DCA Groups: 
 

Using the touch screen

 – Press a DCA master 

Sel

 key. 

The screen opens in the DCA Routing page. 
Touch the tabs within the page to access the assignments 
of the channels, FX and mixes to the DCA Group. Touch the 
buttons to assign to the DCA Group. 
 

Using the GLD fader strips

 - Press a DCA master strip 

Mix

 

key. Current assignments are shown in the source strip 
LCD displays. The ‘ON’ icon displays for sources currently 
assigned. 
While holding down the Assign key press source strip 

Mix

 

keys to toggle assignments on or off. Remember to press 
the master strip 

Mix

 key again to return to the main mix. 

 

DCA Fader to 0dB option

 – Select this if you want to use 

the DCA as a 

Mute Group

. This disables the DCA master 

fader and sets it to its ‘0’ position. If you try to move the 
fader it will return to this position. Use the DCA Mute key as 
the Mute Group master. 
 

DCA Groups explained

 

A DCA group provides a master fader and mute to remotely 
control the level of channels assigned to it. 
Audio does not route through DCA groups as it does 
through conventional mix Groups. GLD provides both types 
of grouping. Use DCA Groups for level control and mute 
grouping. Use Mix Groups for grouped signal processing 

such as compression and for routing of grouped signals to 
Aux or Matrix mixes. 

 
The DCA master affects the level and mute of an assigned 
channel back at its fader point. It is another level stage in 
line with the channel fader. It does not physically move the 
channel fader. A separate indicator next to the channel 

Mute key shows if it is muted by one or more DCA groups. 
Channels can be assigned to multiple DCA Groups. For 
example, drum channels could be assigned to a DRUM 
DCA and also to a BAND DCA. 
 

To use DCA Groups

 

Assign channels to the DCA Group. 
Set the DCA master fader to its ‘0’ position. This is its 
normal operating position. This position results in the same 
level as if the channel was not assigned to the DCA. 
You can adjust the level of the assigned channels up or 
down using the master fader, but always start with it set to 
‘0’. 
 

Note

  If you get no signal when you raise a channel fader 

check that it is not turned off by a DCA master. 

 

 

Содержание DIGITAL MIXING SYSTEM

Страница 1: ...DIGITAL MIXING SYSTEM Screen Reference Guide For GLD firmware Version V1 2 Check the Allen Heath web site for the latest version available Also read the GLD User Guide AP8561...

Страница 2: ...e Manager page 31 7 2 Scene Recall Filter page 32 7 3 Cue List Editor page 33 7 4 Scene Safes page 34 8 Ganging Screen 35 9 Setup Screen Audio 36 9 1 PAFL Setup page 36 9 2 Talkback Setup page 36 9 3...

Страница 3: ...a User Scene is set it is recalled automatically on login when the user is changed It does not recall when the same user logs in or when the system is powered up again while the same user is current...

Страница 4: ...ectly may result in parameter changes made up to 30 seconds before power is removed becoming lost Lock Surface Touch the Lock Surface button and Yes in the confirmation popup to lock the surface contr...

Страница 5: ...e master Master faders Channel faders Aux3 Aux3 Aux3 Sel Mix Sel Mix Preamp PEQ LF HPF GATE Routing LM HM HF Gain Normal mix mode FOH Master Mix Channel Mix Assign Routing Assign Routing Pre Post Sel...

Страница 6: ...are stored in Show memories 3 2 Overview page Input Channel Input Channel processing pages are accessed by pressing an Input strip Sel key while the Processing screen is selected The Input Overview p...

Страница 7: ...cted mix For a view of all Mix Channel delays open the Delay page Library The Mix Channel Library is accessed from the Overview page 3 4 Overview page FX Send or Return FX processing pages are accesse...

Страница 8: ...call Preamp button setting is remembered when changing channels 3 6 Preamp page The Preamp page provides access to the Input Channel source patching socket Preamp settings and channel Trim and HPF Tou...

Страница 9: ...PTIONS pull up window Provides a global setting for Preamp or Trim on Surface This affects all input channels Touch the pull up tab and swipe your finger upwards to open its window A note about Gain S...

Страница 10: ...te on a rack tom to open In Switch the gate in or out of circuit The side chain can also be switched in or out of the gate The curve turns yellow and the gain reduction meter displays red when the gat...

Страница 11: ...ands is available Sel button Touch while holding the Copy Paste or Reset key to copy the PEQ settings to other channels or to reset it flat 3 12 GEQ page A 28 band 1 3 octave Graphic Equaliser is prov...

Страница 12: ...while in any of the mix Processing pages This puts the lower frequency half of the GEQ on to the faders Press again to present the higher frequency half and press again to return to normal fader mode...

Страница 13: ...level Attack and Release These controls set how fast the compressor pulls back the signal when it exceeds the threshold and how long it takes to let go when the signal drops below the threshold Set t...

Страница 14: ...en the Routing page for the currently selected Input Channel Touch the tabs within the page to access the assignments and send levels from the selected Input Channel to all Groups Auxes and FX its DCA...

Страница 15: ...s are shown in the channel strip LCD displays For example with an Aux master selected Sends from all channels to the mix Sends from all FX returns to the mix Sends from all audio Groups to the mix Whi...

Страница 16: ...this position Use the DCA Mute key as the Mute Group master DCA Groups explained A DCA group provides a master fader and mute to remotely control the level of channels assigned to it Audio does not ro...

Страница 17: ...all meters in the Inputs page This does not affect the fader strip or other screen metering The following options are available all Pre Fader Post Trim Post Gate PEQ Post Compressor Post Delay Defaul...

Страница 18: ...octave Real Time Analyser frequency display for the signal currently PAFL signal The RTA can be viewed in the Home or Meters screens It also displays on the strip meters when GEQ Fader Flip is active...

Страница 19: ...then check that the related Send master and Return faders are turned up and that they are not muted or affected by a DCA Group PEQ Each FX Return has a 4 band Parametric Equaliser Touch the PEQ button...

Страница 20: ...e SMR Reverb SMR Live is a Spatial Modelling Reverberator featuring 4 fully configurable complex spatial models Classic Hall Room and EMT Each of these models use different reflection and decay algori...

Страница 21: ...ft and right delay can be dialled in using the screen Rotary tapped on screen or tapped using a SoftKey Individual tap indicators flash at the tap rate The left and right delay taps can be ganged to m...

Страница 22: ...brary window ADT Doubler An Automatic Double Tracking module capable of creating short echo chorusing classic double tracking and slapback tape delay loops The ADT is very effective in creating stereo...

Страница 23: ...n sine wave and rectified LFO modulator Autopan Automatically pans the chorus voices wet signal only not the dry signal This is level modulation of the wet effect not the dry signal across the stereo...

Страница 24: ...n untameable dramatic effect The sound turns inside out Preset Name is displayed Touch and scroll using the screen Rotary for live update This is a way of live auditioning all library presets for this...

Страница 25: ...both Left and Right signal paths and presented on one meter UPPER FREQ CUT Controls the upper bandwidth of the sub bass harmonic spectrum This setting depends greatly on the sub bass speaker equipmen...

Страница 26: ...resets for this module factory user and USB You can also select and recall a particular preset using the Library window Rotator The Rotator is a model of a traditional rotary speaker cabinet such as t...

Страница 27: ...results in both voices being set to zero Preset Name is displayed Touch and scroll using the screen Rotary for live update This is a way of live auditioning all library presets for this module factory...

Страница 28: ...o assign a range of output sockets touch the End box and turn the screen rotary The sockets about to be assigned are highlighted on the screen Touch Apply to accept the assignment or Cancel to discard...

Страница 29: ...box and turn the screen rotary The outputs about to be assigned are highlighted on the screen Touch Apply or Cancel to accept or discard the change Touch the Polarity button to reverse the polarity o...

Страница 30: ...p to the MMO sockets as below GLD Port Map Port Out MMO ADAT 1 ADAT 1 2 ADAT 2 3 ADAT 3 4 ADAT 4 5 ADAT 5 6 ADAT 6 7 ADAT 7 8 ADAT 8 9 ADAT 9 10 ADAT 10 11 ADAT 11 12 ADAT 12 13 ADAT 13 14 ADAT 14 15...

Страница 31: ...e you wish to copy Touch the Copy button Touch the Scene you wish to copy to Touch the Paste button to paste the contents and filter settings to that Scene Note Copying a Scene copies its contents and...

Страница 32: ...Block All or Allow All button at bottom left Touch Close to return to the main Scene Manager view 5 4 3 2 1 Close Scene Recall Filter parameters For Inputs FX Returns FX mix Grp Aux Main Mtx Preamp G...

Страница 33: ...ers in the list To remove Scenes from the Cue List Touch the trash can icon to the right of the Scene name This removes it from the Cue List but not the All Scenes list To clear all Scenes from the Cu...

Страница 34: ...parameters for one channel Touch label on left 4 All items in the current tab Touch Toggle All Safes are applied immediately No confirmation is needed Safes settings are stored in Show memories 4 3 2...

Страница 35: ...g the Routing attribute links the assignments and sends from the ganged channels Touch Apply or Cancel to accept or delete the changes Using Gangs Use the Gangs to suit the way you prefer to mix Some...

Страница 36: ...tor mixing Mix follows Mix PAFL Pressing a Mix master strip PAFL key selects Mix for that master Mix follows Input PAFL Pressing an Input channel strip PAFL key selects Mix for that channel Sel follow...

Страница 37: ...setting Note The Signal Generator is disabled while Talk is active 9 3 SigGen page The Signal Generator SigGen is a useful tool providing a steady test signal to help you align and test a live sound s...

Страница 38: ...188KB sec Therefore allow 11 5MB per minute 700MB per hour Note Maximum recording time for one track 3 hours To assign a recording source Touch the Assign button to open the I O Surface screen to pat...

Страница 39: ...r console is the Master and has control of the mic preamps in AudioRacks connected to it This console is set for Internal audio clock source FOH console This console is the Slave getting its mic input...

Страница 40: ...up window Use the pull up to choose to sync the Layer shown on the screen with the currently selected surface Layer Select the Bank to work with The screen will follow the Layer currently selected on...

Страница 41: ...stom MIDI message string Talkback Assign Talkback to different outputs Level Up Tap to increase level for faders Level Down Tap to decrease level for faders Send Level Up Tap to increase level for Aux...

Страница 42: ...alternative information display on the fader strip LCD while it is held To choose an Alt View option Open the drop down menu and touch an item to select it Alt View display options The strip LCD norm...

Страница 43: ...eset Shows are not cleared during a firmware update To Store a new Show Touch the Store Show button Type in a name using the keypad Touch Apply Touch OK in the popup to return to the Show list To over...

Страница 44: ...r bank assigned with input channels 11 3 Library Manager page Use this page to edit and transfer User and USB Libraries Library memories include Channel Processing Preamp option Mix Processing PEQ GEQ...

Страница 45: ...x with independent stereo LR and mono M buses Channels can be separately assigned to any combination of LR and M Typical application for M is main centre speaker mono PA or bus fed sub bass LCR A 3 wa...

Страница 46: ...ed in The Admin user Administrator has access to all functions and can set permissions and allocate passwords if required for the other users Up to 9 other Users may be set up for example volunteer op...

Страница 47: ...user at any time by going to the Home Users screen You can also change user at the Login screen when powering up the GLD if a password has been set If a password has been set then you are also prompte...

Страница 48: ...ng the settings Changing these settings will automatically restart the touch screen 13 3 Calibration Setup page The Calibration Setup page lets you recalibrate the accuracy of the touch screen or moto...

Страница 49: ...will not load on systems running earlier versions However earlier versions of Shows will load on GLD running later versions of firmware Features introduced on more recent firmware will not be recalle...

Страница 50: ...a Show go to the Setup Memories Show Manager screen Loading a Template Show will Restore a default configuration and layout Reset user preferences Zero the board current settings Reset the processing...

Отзывы: