08-19-04 Z08-02830B
1.
LOCATION
: This machine should be installed
by only qualified technicians. The machine should
be set upon a level surface where it will not be
affected by strong winds, rain, snow, extreme heat,
and freezing temperatures. Install the machine
considering locations for chemical pick-up, fuel
connections, electrical connections, water hook-up,
venting, and maintenance.
All wiring and electrical connections should
comply with the National Electrical Code (NEC) and
with local codes and practices. Use the chart on the
next page for your cord selection
2.
ELECTRICAL
: Connect machine to an electrically
grounded circuit that is fused or circuit breaker
protected. The circuit must match that specified in
the ELECTRICAL section under
MODEL
SPECIFICATION
3.
EXTENSION CORD
: The use of an extension cord
that has undersize wire compared to the amp draw of
your machine will adversely limit the starting load
carrying abilities of the motor and machines
performance. Use only 3-wire extension cords that
have 3-prong plugs and 3-pole cord connectors that
accept the plug from the product. Use only extension
cords that are intended for outdoor use. These
extension cords are identified by a marking
“Acceptable for use with outdoor appliances; store
indoors while not in use.” Use only extension cords
having an electrical rating not less than the rating of
the product. Do not use damaged extension cords.
Use an extension cord in good repair free of frays or
cracks in the outer covering. Do not abuse extension
cord and do not yank on any cord to disconnect.
Keep cord away from heat and sharp edges. Always
disconnect the extension cord from the receptacle
before disconnecting the product from the extension
cord.
COP P E R
W IRE SIZE
M INIM UM
A W G
M ACHINE AM P
DRAW *
3 CONDUCTOR
W IRES
M A C H I N E A M P
DRAW *
2 CONDUCTOR
W IRES
16
10
13
15
--
--
14
15
18
12
20
25
10
25
30
8
35
40
6
45
55
4
60
70
2
80
95
5
WARNING: ELECTRICAL SHOCK
HAZARD
WARNING
: To reduce the risk of electrocution,
keep all connections dry and off the ground. Do not
touch plug with wet hands.
CHART FIGURES ARE BASED ON NOT
MORE THAN 100 FOOT
(Based on Ambient Temperature of 86°F (30°C)).
*Use Amp Draw indicated the same or higher than your
machine output
EXAMPLE
: Machine Amp Draw 51, use 55 (2 Conductor).
The thermostat type of cord shall be C, PD, E, EO, EN,
S, SO, SRD, SJ, SJO, SV, SVO, SP.
The thermo set plastic types shall be ET, ETT, ETLB,
ETP, ST, STO, SRDT, SJT, SJTO, SVT, SVTO, and SPT.
4
. VENTING: This
machine emits carbon monoxide, a
deadly gas, and must be vented if used in an enclosed
area. Improper venting can cause poor combustion,
delayed ignition, down drafts, and the possibility of
freezing the coil. Contact your distributor or local
heating and air conditioning dealer for proper
materials. Local codes must be observed.
WARNING:
CARBON MONOXIDE
HAZARD
INSTALLATION
08-15-03 Z08-02830
Содержание 3102 Series
Страница 1: ...P O Box 288 105 Broad Street Alcester SD 57001 800 255 6823 www alkota com OLD VALUES NEW IDEAS 3102 ...
Страница 21: ...12 12 02 Z08 00064S ECN 02897 Supersedes 09 00 Z08 00064 7 ...
Страница 22: ...09 00 Z08 00064 ECN 02311 7 ...
Страница 25: ......
Страница 26: ......
Страница 37: ......
Страница 42: ...06 13 06 Z08 00061 BREAKDOWN BURNER OIL 115V 1PH 60HZ EXPLODED VIEW P N V00 17365 2 Supersedes 04 92 Z08 00061 ...
Страница 43: ...4 ...
Страница 44: ...14 ...
Страница 47: ......
Страница 48: ......
Страница 50: ......