W 3 2 S E R I E S
H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R
41
open and leak at the pressure stated on it. If the safety valve does not open, stop the compressor
without waiting for the pressure to rise up.
15.
Fill in the commissioning report and technical data forms. Return a copy to the manufacturer for
tracking record.
1.12.2 Oil Recommendation
The oil level should be checked before each start up. Top up to the overfill point when required
3 liters
of oil
should be loaded during each replacement.
RECOMMENDED OILS
OIL TRADEMARK
Typ
Quantity
Anderol 750
Synthetic
3 liter
Chemlube 751
Synthetic
3 liter
•
Do not use another type of oil without prior written approval of the compressor manufacturer.
•
Do not mix different brand and type of oils.
•
If you will change the oil you use with another approved brand of oil, load the new oil after you make
sure that you drain the old oil completely in the crankcase.
•
Refill the oil every 6 months unless you reach the replacement time of the oil stated in the
maintenence table.
•
Initial oil replacement must be performed at 300 hours. After the initial replacement oil should be
replaced every 1000 hours of operation.
1.12.3 Extremely Cold Ambient Temperatures
Operating conditions out of the stated conditions must be reported to the compressor manufacturer to make
the necessary changes to adopt the compressor to the current conditions. For instance if the compressor
needs to work in an extremely cold ambient temperature below freezing temperatures a crankcase heater is
attached to the crankcase of the compressor to prevent the negative effect of the cold ambient temparatures.
1.12.4 Motor Lubrication
Electric motors on W32 Series compressors are supplied with greased and sealed bearings. They do not no need
further maintenance. See the users manual of electric motors or petrol engines before operating your compressor
and follow the instructions while using your compressor.
1.12.5 Adjustments
Pressure Switch Adjustment (Only available on Automatic Start/Stop
Controlled W32 Canopy and Mariner Models
Pressure adjustment on Automatic Start/Stop Controlled W32 Mariner Compressors is
made according to the following steps: You can adjust PH1 pressure switch to the required
upper pressure (working pressure) by turning the screw on the pressure switch clockwise
or anti-clockwise. Turn the screw clockwise to increase the upper pressure. In this case you
may also need to change the safety valve as it is set to open when it reaches the upper
pressure. Turn the screw anticlockwise to decrease the upper pressure. Compressor is
already set in the factory upon the customers working pressure needs. You can adjust the
working pressure if you need a higher or lower working pressure than the factory settings. Compressor will stop
when it reaches the adjusted upper pressure.
Standard Pressure Switches used on Alkin Automatic Start/Stop controlled W32 Mariner units have standard
differential of 20 Bar. In other words lower pressure is set automatically at 20 Bar below the upper pressure limit
Содержание W32 Canopy
Страница 1: ...W32 SERIES...
Страница 3: ...InstructionsManual and Parts List...
Страница 4: ......
Страница 10: ...W 3 2 S E R I E S H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R ALKIN COMPRESSORS 10...
Страница 46: ...W 3 2 S E R I E S H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R ALKIN COMPRESSORS 46...
Страница 60: ...W 3 2 S E R I E S H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R ALKIN COMPRESSORS 60...
Страница 66: ...W 3 2 S E R I E S H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R ALKIN COMPRESSORS 66...
Страница 88: ...W 3 2 S E R I E S H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R ALKIN COMPRESSORS 88...
Страница 94: ...W 3 2 S E R I E S H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R ALKIN COMPRESSORS 94...
Страница 100: ...W 3 2 S E R I E S H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R ALKIN COMPRESSORS 100...
Страница 106: ...W 3 2 S E R I E S H I G H P R E S S U R E B R E A T H I N G A I R C O M P R E S S O R ALKIN COMPRESSORS 106...