56
PRELIMINARY
SECTION 5: OSD MENU REFERENCE
2.
Configure the interval of the alarm sequence.
When more than one alarm of the same priority occurs at the same time, the camera will respond to one alarm first and
then respond to the next one after the user-defined interval. You can set the on ALARM SEQUENCE submenu from 1 to 200
seconds.
3.
Configure the alarm rest delay.
If there’s a linkage action has already been triggered by an alarm input, the camera will only respond to the input from the
same channel again after the user-defined reset delay time. This is the rest time that the camera considers an alarm to be
active when it’s physically cleared. You can set the ALARM REST DELAY from 0 to 300 seconds.
4.
Resume the dome activity.
You can set ALARM RESUME to ON to enable the camera to resume its previous activity after the triggered actions finished.
NOTE
•
If the camera is moving when a linkage action is triggered, it will stop at the current position and resume from this position after the
linkage action finishes.
•
The camera can be configured to resume the PTZ positions, focus and iris value.
5.3.3 AUXS submenu (Auxiliary alarm output)
An auxiliary output is a configurable alarm output interface on the camera back box which can connect and trigger another alarm
device to operate. You can configure two auxiliary outputs.
1.
Open the alarm auxiliary output configuration submenu (AUX). Go to
MAIN MENUS
g
DOME SETTINGS
g
AUXS
2.
Click
IRIS+
to edit the status of the auxiliary outputs. You can set the alarm output type as OPEN (normally open) and CLOSE
(normally closed).