WARNING

 

NEVER ADJUST THE BURNER SO LOW THAT IT MAY 
GO OUT DURING USE. DO NOT OPERATE THE SIDE 
BURNER WITH THE LOW HEAT SCREW REMOVED. 
 

GAS CAN ESCAPE AND CAUSE A POTENTIALLY 

HAZARDOUS CONDITION. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTE:  
The first burner may take longer to light while air is purged from the gas supply system. 
 
If the burner does not light in 4 seconds, turn knobs to “OFF” and wait 5 minutes to allow any accumulat-
ed gas to dissipate before trying again. If the burner will not light after several attempts, then it can be     
lit with a match. 
 
Keep your face away  from the Side Burner as far as possible and pass a lit, long stem match through 
the  Side  Burner  grate the  ports  of  the  burner  you  are  trying  to  light. When attempting  to  light  a  burner 
with a match, ensure that the correct burner control knob is used. 
 
Position the match near the burner ports. Push and turn the control knob to “HI”. Repeat procedure on 
each burner if necessary.  If the burner does not light in 4 seconds turn the knob OFF, wait 5 minutes 
and try again.  If the burner will not light after several attempts see page 14: Troubleshooting. 
 
 
BUTTON SYMBOLS AND LOCATIONS: 
 
There is only one button to engage the igniter located on the upper 
right corner of the front panel of the Side burner. 
 
 
 

BURNER ADJUSTMENTS 

 
LOW HEAT SETTING ADJUSTMENT: 
 
 
NOTE: 
THE  LOW  HEAT  SETTING  ON  YOUR 
SIDE  BURNER  IS  PRESET  AT  THE 
FACTORY. 
ADJUST  ONLY  IF  ALTITUDE  OR  ENVI-
RONMENTAL FACTORS ARE CAUSING 
POOR, LOW  HEAT, PERFORMANCE. 
 
 

IGNITER BUTTON SWITCH 
(on RIGHT side) 

PUSH TO 
IGNITE 

PUSH & TURN TO “HI” 

Figure # 4

 

Содержание ALSB-2

Страница 1: ......

Страница 2: ...2 PASTE SERIAL NUMBER LABEL IN THIS LOCATION NOTES BARBEQUE SERIAL NUMBER LABEL ...

Страница 3: ...al Gas Installation code or CAN CGA B149 2 Propane Installation code All components must be grounded in accordance with local codes or with the National Electrical Code ANSI NFPA 70 990 or Canadian Electrical code CSA C22 1 CALIFORNIA PROPOSITION 65 WARNING The burning of gas cooking fuel generates toxic by products which are on the list of substances which are known by the State of California to ...

Страница 4: ...ky cloth in place of potholders Do not let potholders touch hot por tions of the Side Burner grate Only certain types of glass heatproof glass ceramic earthenware or other glazed utensils are suita ble for Burner use These types of materials may break with sudden temperature changes Use only on low or medium heat settings and according to their manufacturer s directions Grease is flammable Let hot...

Страница 5: ...ntrols are turned off and the Side Burner is cool before using any type of aerosol cleaner on or around the Side Burner The chemical that produces the spraying action could in the presence of heat ignite or cause metal parts to corrode Do not operate the Side Burner under unprotected combustible construction Use only in well ventilat ed areas Do not use in buildings garages sheds breezeways or any...

Страница 6: ...1 Remove all packaging materials 2 Install and secure the body of the Side Burner to your counter s enclosure 3 Ensure that the burners are positioned correctly on their venturi funnels and are fully seated onto their supports See figure 1 4 Install the Side Burner Grate 5 Make the connection to the gas regulator according to the instructions on pages 8 9 for your gas type 6 To comply with safety ...

Страница 7: ...0 0 W C Non operating 11 2 W C L P TANK REQUIREMENTS Use only a standard 20 Lb 5 Gal propane gas cylinder 18 1 4 H x 12 1 4 Ø The tank must be installed in the upright position Do not use a dented or rusty LP tank as it may be hazardous and should be checked by your LP supplier Never use a cylinder with a damaged valve The LP gas cylinder must be constructed and marked in accordance with the speci...

Страница 8: ...it Verify that the a 1 2 FPT x 1 2 MPT male to female connected to the regulator points in the required direction see Figure 2 Fasten the hose connection to a 1 2 MPT x 3 8 COMP compression flare fitting connected to the elbow see Figure 2 LP GAS CONNECTION TO LP PIPED SYSTEMS An LP piped system is one with a large central LP tank that feeds the entire household Those systems are normally equipped...

Страница 9: ...re that the service pipe supplying the Side Burner is fitted with a shut off valve conveniently posi tioned and easily accessible as an emergency gas shutoff Your ALFRESCO Side Burner for use with Natural Gas comes equipped with its own regulator which MUST NOT be removed If this regulator needs to be replaced use only the type specified by ALFRESCO for this appliance CAUTION CYLINDERS MUST BE STO...

Страница 10: ... Burner Verify that the a 1 2 FPT x 1 2 MPT male to female connected to the regulator points in the required direction see Figure 3 Fasten the pipe or hose connection to a 1 2 MFT elbow with the ap propriate gas fittings see Figure 3 If the connection of the Side Burner is done with flare fittings and a flexible hose to the existing NG gas supply a 1 2 diameter flexible stainless steel gas hose no...

Страница 11: ...YS CHECK FOR LEAKS AFTER EVERY LP TANK CHANGE If a leak is present or if the connection hose shows signs of wear these conditions must be corrected prior to using your Side Burner Check all gas supply fittings for leaks before each use It is handy to keep a spray bottle of soapy water near the shut off valve of the gas supply line Spray all the fittings Bubbles indicate leaks LIGHTING INSTRUCTIONS...

Страница 12: ... burner you are trying to light When attempting to light a burner with a match ensure that the correct burner control knob is used Position the match near the burner ports Push and turn the control knob to HI Repeat procedure on each burner if necessary If the burner does not light in 4 seconds turn the knob OFF wait 5 minutes and try again If the burner will not light after several attempts see p...

Страница 13: ...to this reputation DAY TO DAY CARE To maintain the original appearance of your ALFRESCO Side Burner a regular cleaning routine should be carried out using the following guidelines 1 After use following the safety precautions detailed on page 4 and 5 wipe the Side Burner with a soft damp soapy cloth and rinse with clean water preferably warm hot water This should remove most substances encountered ...

Страница 14: ...occurs in stainless steel is pitting of the surface The rea son for this corrosive attack can usually be attributed to certain household products for example Bleaches Most common domestic bleaches sterilizing solutions contain chlorine in the form of sodium hypo chlorite If used in concentrated form bleaches can attack the stainless steel causing pitting of the sur face They should always be used ...

Страница 15: ...IDERATIONS In order to maintain your Side Burner in clean working order it will be necessary under certain conditions to take additional precautions If your Side Burner is located in a coastal area it will be exposed to salty air which is corrosive If it is located close to a swimming pool or Jacuzzi with chlorinated water then it will be exposed to dilute hydrochloric acid which can be formed as ...

Страница 16: ...can enjoy many years of service from it and keep it looking the way it should In the event that any light rusting is found on the stainless steel it will usually not be the stain less steel which is corroding but iron particles which have somehow been deposited on the sur face For more information on this subject please request our Rust removal bulletin As a first course of action though we recomm...

Страница 17: ...17 ...

Страница 18: ...per left corner Gas Type Date of installation A brief description of the problem INQUIRIES AND INFORMATION For all other Alfresco Gourmet Grill information such as power installation cut out requirements or any other product inquiries please contact Alfresco Gourmet Grills 888 383 8800 or 323 722 7900 Customer Service Department 323 726 4700 fax 7039 East Slauson Avenue Commerce CA 90040 Or visit ...

Страница 19: ...com or call 866 203 5607 to report service problems and or to obtain replacement parts for your Alfresco Side Burner Replacement parts are shipped F O B Commerce California 90040 Before calling for service please make sure you have the following information Model number serial number date of purchase and proof of purchase by original owner Limitations Exclusions 1 Alfresco s warranty applies only ...

Страница 20: ...20 ...