GAS CONNECTION—LIQUID PROPANE (LP)
NEVER CONNECT THE SIDE BURNER TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury. Total gas consumption (per hour) with all
burners set on “HI” is a follows:
•
ALSB2
40,000 BTUH
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1988. Installation in Canada must be in accordance with the
Standard CAN/ CGA-B149.1 Natural Gas Installation or CAN/CGA-B149.2, Propane Installation Code.
Manifold pressure with LP
Operating:
10.0” W.C.
Non-operating:
11.2” W.C.
L.P. TANK REQUIREMENTS:
Use only a standard 20 Lb. (5 Gal.) propane gas cylinder (18-1/4” H x 12-1/4” Ø). The tank must be
installed in the upright position. Do not use a dented or rusty LP tank as it may be hazardous and should
be checked by your LP supplier. Never use a cylinder with a damaged valve.
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas
cylinders of the U.S. Department of Transportation (DOT). The cylinder must be provided with a shut off
valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection type
QCC1 in the standard for compressed gas cylinder valve outlet and inlet connections ANSI/CGA-V-I.
Figure # 1
GRATE
EXTERNAL CAP
SIDE BURNER BODY
REGULATOR
LOCATION
INTERNAL CAP
ORIFICE
VENTURI FUNNEL
PIPE FITTING
ELECTRODE
ASSEMBLY
TOP COVER
BURNER PARTS: