10
CAUTION
CYLINDERS MUST BE STORED OUTDOORS IN A WELL VENTILATED AREA OUT OF THE
REACH OF CHILDREN.
DISCONNECTED LP CYLINDERS MUST HAVE THREADED VALVE PLUGS TIGHTLY INSTALLED, AND MUST NOT
BE STORED IN A BUILDING, GARAGE OR ANY OTHER ENCLOSED AREA. THE GAS MUST BE TURNED OFF AT
THE SUPPLY CYLINDER WHEN THE UNIT IS NOT IN USE. IF THE APPLIANCE IS STORED INDOORS, THE CYL-
INDER MUST BE DISCONNECTED AND REMOVED FROM THE APPLIANCE.
WARNING
ENSURE THAT THE GAS
SUPPLY HOSE DOES
NOT COME IN CONTACT
WITH THE OVEN BODY
The cylinder must be provided with a shut off valve terminating in an LP gas supply cylinder valve outlet
specified, as applicable, for connection type QCC1 in the standard for compressed gas cylinder valve
outlet and inlet connections ANSI/CGA-V-I.
LP GAS CONNECTION TO LP TANKS:
Your
Alfresco
™ Pizza Oven for use with LP gas comes equipped with its own regulator, which MUST
NOT be removed. The oven is shipped with high capacity, hose/regulator assembly for connection to a
standard 20 Lb. LP cylinder. The LP gas pressure regulator and hose supplied with this oven must be
used without alteration.
If this assembly needs to be replaced, use only the type specified by
Alfresco
™ for this appliance.
Pizza ovens require a 60,000 BTUH minimum regulator / hose assembly.
To connect the regulator / hose assembly follow the
next steps:
•
Locate the regulator and gas connection point in
the rear left side of your Oven unit
•
Fasten the hose connection to the 1/2” MPT x
3/8” COMP (compression flare fitting) connected
to the elbow. (See Figure # 4).
Figure # 4
1/2” FPT X 3/8” FLARE
BRASS FITTING ON
TYPICAL LP
GAS TANK
LP REGULATOR AND HOSE
ASSEMBLY (PRESET TO 10” WC)
ELECTRICAL
CORD PLUG
Содержание ALF-PZA
Страница 1: ......
Страница 2: ...2 PASTE SERIAL NUMBER LABEL IN THIS LOCATION NOTES ALF PZA SERIAL NUMBER LABEL ...
Страница 31: ...31 NOTES ...
Страница 32: ...32 ...