background image

23 

 

 

 Special maintenance 

Special  cleaning  and  maintenance  activities  (types  2  and  3)  help  the  furnace  keep  its  heating  and  functional 

characteristics for longer. 

To ensure that the maintenance of the furnace is not in vain, it is necessary to maintain the system for removing smoke 

with the same diligence. 

 

 

SPECIAL MAINTENANCE TYPE 2 ACTIVITIES    

In  addition  to    type  1  maintenance  activities,  type  2  maintenance  activities  must  be  carried  out  after  about  350-400 

working hours, or otherwise after about 500 ~ 600 kg of used fuel. 

 ATTENTION: Any cleaning activity must be carried out when the furnace is completely cold and disconnected from the 

power supply (with a cable unplugged from the socket). 

 ATTENTION: Make sure that the ash is completely cold before you start cleaning the furnace.  When you make sure the 

ash is cold, you can clean it with a vacuum cleaner. 

Periodic type 2 maintenance activities are carried out in accordance with the following procedure: 
 

1.

 

Lift and slide the heat-resistant plate on the top of the furnace inward so that the lower part is sticking out. 

 

2.

 

Take the heat-resistant plate with both hands and tilt it from the combustion chamber making sure that the plate 

does not hit other parts of the furnace. 

 

 

3.

 

Thoroughly clean the entire back part of the heat exchanger using the attached brush and  a vacuum cleaner to 

clean up all the soot and ashes that come out of the heat exchanger, 

 

 

After you've finished cleaning, re-assemble all the elements in reverse order from the order in which you removed them. 
 

 

SPECIAL TYPE 3 MAINTENANCE ACTIVITY  

These activities should be carried out at the end of the season, along with the type 1 of routine maintenance activities 

and special type 2 maintenance activities. 

These special maintenance activities serve to clean the engine smoke and its cabinet, as well as to carry out a thorough 

cleaning of the lower part of the heat exchanger. 

You should perform these activities from both sides of the furnace by removing the outer insulation (see the instructions 

with the isolation kit for removing the housing). 

 ATTENTION: These activities should be performed by an authorized person. 

 ATTENTION: Any cleaning activity must be carried out when the furnace is completely cold and disconnected from the 

power supply (with a cable unplugged from the socket). 

 ATTENTION: Make sure that the ash is completely cold before you start cleaning the furnace. When you make sure the 

ash is cold, you can clean it with a vacuum cleaner. 

Engine smoke and its housing can be cleaned by following the activities described below: 
 

1. 

After lifting and removing the lid, you can lift up and remove the left side. Do the same on the right side. 

That’s how you can get excellent access to the engine smoke. 

 

Engine smoke 

Содержание LUCA 12

Страница 1: ...A D METALNA INDUSTRIJA VRANJE Radni ka br 1 PELLET STOVE LUCA 12 INSTRUCTIONS FOR USE AND MAINTENANCE OF LUCA 12 ENG_v 1 0...

Страница 2: ...perature gauge 9 Using the Product 9 The necessary checks and controls for the first ignition 10 Loading the fuel 10 Control System of the Furnace 10 Electrical connection scheme 10 The control panel...

Страница 3: ...E FURNACE 19 Routine maintenance 19 CLEANING THE DISPLAY AND PARTS OF EXTERNAL INSULATION 19 CLEANING THE CERAMIC GLASS 19 ROUTINE MAINTENANCE TYPE 1 ACTIVITY 20 Special maintenance 23 SPECIAL MAINTEN...

Страница 4: ...ide The following symbols are used in this user guide ATTENTION Safety warning PROHIBITED Prohibited action INFORMATION Important information Alfa Plam bears no responsibility or liability for any dir...

Страница 5: ...2 Dimensional features...

Страница 6: ...Hz 50 Fuel Wood pellet Fuel consumption per hour kg h 2 7 5 The flow of gas masses g s 9 0 3 3 Combustion gas temperature C 128 57 Minimum withdrawal pressure Pa 12 0 12 0 Tank capacity kg 14 Autonomy...

Страница 7: ...g dm3 1 12 1 0 1 4 1 12 0 6 average mass volume Humidity 10 12 10 10 Ash 0 50 1 50 0 50 0 50 Thermal power kWh kg 5 4 86 5 42 5 4 5 Sulfur 0 04 0 08 0 04 0 05 Nitrogen 0 3 0 3 0 3 0 3 Chlorine 0 02 0...

Страница 8: ...ake all the necessary precautions particularly when children or elderly or disabled people are present ATTENTION Do not block or clogs the hot air drain in any way Do not cover the product with cloth...

Страница 9: ...made of non flammable materials is PROHIBITED Using the product in explosive and potentially explosive atmospheres is PROHIBITED Installation You must comply with all local and national laws and Euro...

Страница 10: ...cm Minimum distance from combustible rear wall B 50 cm Minimum distance from combustible side wall S 40 cm Minimum distance from combustible material on the front side Fr 150 cm Once you ve determined...

Страница 11: ...f the solutions that can be applied includes storing the furnace that uses wood pellets near the outer wall of the house so that the exhaust fumes are directly released outside Figure 2 4 Some of the...

Страница 12: ...rmful No special conditions are needed for its disposal The user is responsible for the disposal of the remaining components of the packaging The user must follow the proper disposal procedures in acc...

Страница 13: ...ATTENTION Do not let the bag with wooden pellets come into contact with hot parts of the product while you load the fuel ATTENTION Do not remove the protective grid inside the part for loading the pel...

Страница 14: ...ing Main Temp The current value of the room temperature State Functional state of the furnace Main Therm Set room temperature Comb Power Combustion power Heat Power Heating power Time Time Chrono Sche...

Страница 15: ...gnal Block Er47 Auger encoder error auger speed control failed Block Er48 Module error I O 12C Block Er52 Service error This informs that the planned period of operation has been reached after preload...

Страница 16: ...n a distant room It is visible only if the external thermostat is installed while a heating plant that uses it is set up to use an external thermostat Remote Control This menu allows turning the remot...

Страница 17: ...M In the end press P2 in order to activate the program The following is shown on the display Daily Monday ON OFF 09 30 11 1 5 00 00 00 0 0 00 00 00 0 0 This program schedules the furnace to turn on on...

Страница 18: ...up phase the initial checks of the input signals or the probity of safety probes and pressure switches of the furnace are done In this phase the flue gas engine runs at maximum speed while the auger a...

Страница 19: ...hich dispensing of pellets stops and the flue gas engine and the ambient fan operate at maximum capacity in order for the furnace to cool down as soon as possible Minimum duration of the extinguishing...

Страница 20: ...t enters running mode at the end of ignition phase Message Block ignition is shown on the display If an error occurs the system immediately goes into shutdown if P2 is pressed it is possible to immedi...

Страница 21: ...y cable connectors Damage to the display cable connector Contact the service center Er17 Primary air flux meter error Primary air flux meter does not adjust the operation of the furnace The furnace co...

Страница 22: ...t stove or vice versa The smoke extraction duct flue duct and chimney may not be clean or may be nor airtight The point for inserting the flue duct into the chimnex may be flawed The size of theflue d...

Страница 23: ...ctivities is increased in proportion to the intensity of use of the furnace ATTENTION Make sure that the ash is completely cold before you start cleaning the furnace When you make sure the ash is cold...

Страница 24: ...on chamber in the ash container and at the door 7 The inside of the section in which the ash container is located After you ve finished cleaning re assemble all the elements in reverse order from the...

Страница 25: ...22 9 Once in a month unlock the lock mechanism at back side of the stove remove and clean up the chamber lid for collecting dust on the heat exchanger...

Страница 26: ...e heat exchanger using the attached brush and a vacuum cleaner to clean up all the soot and ashes that come out of the heat exchanger After you ve finished cleaning re assemble all the elements in rev...

Страница 27: ...remove all the soot deposited on the stainless steel blade on the engine smoke 5 Vacuum up all the soot deposited inside the base of the engine smoke especially on the left side next to the stovepipe...

Страница 28: ...nd economical way to protect the system from corrosion and to ensure its efficient operation For homes that are not inhabited throughout the year it is recommended to check the stovepipe and funnel at...

Отзывы: