background image

14 

 

Chrono 
Modalit

Chrono  

program 
Pprogram 

Daily 

Weekly 
Week-end 

The system provides three types of programming: daily, weekly and weekend programming. Selection is made by pressing 

P4 and P5 after which the user enters the selected program by pressing P3. 

1.

 

Daily Programming 

The following is shown on the display once the Daily submenu or the daily program is entered: 

 

Days of the week are selected by pressing P4 and P5. When you select the date press P3.  
Setting the activation and deactivation time of the program for the selected day is done as follows:  

 

Enter the change of time (the preset time is blinking) by pressing P3

 

Change the time by pressing P4 or P5. 

 

Save by pressing P3. 

 

Activate ("

” appears) or deactivate the time period ("

” remains) by pressing P2

 
Example: For example, select Monday and press P3. Then press P3 and ON time (time of turning on of the furnace) starts 

blinking. By pressing P4 and P5 you can set up the desired ON time and confirm it by pressing P3. In this way ON time can be 
set up to, for example, 9:30 AM. When ON time is set up press P5 and then the OFF time  (time of turning off of the furnace) 
starts blinking. By pressing P4 and P5 you can set up the desired OFF time and confirm it by pressing P3. In this way OFF 
time
 can be set up to, for example, 11:15 AM. In the end press P2 in order to activate the program. The following is shown on 
the display: 

Daily 
Monday 

  ON 

OFF 

 

   09:30    - 

11:1

 

   00:00    - 

00:0

 

   00:00    - 

00:0

 

 
This program schedules the furnace to turn on on Monday at 9:30 AM and turn off at 11:15 AM. 
Save your settings by pressing P1
 
For daily programming it is possible to switch the program from the previous day to the next day. 
The procedure is as follows: 
Select the day of the week for programming and setting up the turn on and turn off time. 
Set the clock to ON on the previous day at the desired time: e.g., 8:30 PM. 
Set the clock to OFF on the previous day at 11:59 PM. 
Set the clock to ON on the next day at 12:00 AM. 
Set the clock to OFF on the next day at the desired time: e.g., 6:30 AM. 
The system will turn on at 8:30 AM on Tuesday and will turn off at 6:30 AM on Wednesday. 
 

2.

 

Weekly Programming 

In terms of weekly programming, programs are the same for all days of the week. 
 
The following is shown on the display once the Weekly submenu or the weekly 

program is entered. 

 
The programs are activated and deactivated in the same way as with the daily 

programming. 

 

3.

 

Weekend Programming 

In terms of weekend programming it is possible to choose between programs: 

-

 

Mon-Fri   

-

 

Sat-Sun  

 
Selected  programs  will  be  active  from  Monday  to  Friday  or  Saturday  and 

Sunday. 

 
The programs are activated and deactivated in the same way as with the daily 

programming. 

 

Weekly 
Mon-Sun 
  ON 

  OFF 

 

   

00:00

 

  00:00 

 

   00:00    - 

  00:00 

 

   00:00    - 

  00:00 

 

 
 

 

 

Week-end 
Mon-Fri 
  ON 

  OFF 

 

Содержание LUCA 12

Страница 1: ...A D METALNA INDUSTRIJA VRANJE Radni ka br 1 PELLET STOVE LUCA 12 INSTRUCTIONS FOR USE AND MAINTENANCE OF LUCA 12 ENG_v 1 0...

Страница 2: ...perature gauge 9 Using the Product 9 The necessary checks and controls for the first ignition 10 Loading the fuel 10 Control System of the Furnace 10 Electrical connection scheme 10 The control panel...

Страница 3: ...E FURNACE 19 Routine maintenance 19 CLEANING THE DISPLAY AND PARTS OF EXTERNAL INSULATION 19 CLEANING THE CERAMIC GLASS 19 ROUTINE MAINTENANCE TYPE 1 ACTIVITY 20 Special maintenance 23 SPECIAL MAINTEN...

Страница 4: ...ide The following symbols are used in this user guide ATTENTION Safety warning PROHIBITED Prohibited action INFORMATION Important information Alfa Plam bears no responsibility or liability for any dir...

Страница 5: ...2 Dimensional features...

Страница 6: ...Hz 50 Fuel Wood pellet Fuel consumption per hour kg h 2 7 5 The flow of gas masses g s 9 0 3 3 Combustion gas temperature C 128 57 Minimum withdrawal pressure Pa 12 0 12 0 Tank capacity kg 14 Autonomy...

Страница 7: ...g dm3 1 12 1 0 1 4 1 12 0 6 average mass volume Humidity 10 12 10 10 Ash 0 50 1 50 0 50 0 50 Thermal power kWh kg 5 4 86 5 42 5 4 5 Sulfur 0 04 0 08 0 04 0 05 Nitrogen 0 3 0 3 0 3 0 3 Chlorine 0 02 0...

Страница 8: ...ake all the necessary precautions particularly when children or elderly or disabled people are present ATTENTION Do not block or clogs the hot air drain in any way Do not cover the product with cloth...

Страница 9: ...made of non flammable materials is PROHIBITED Using the product in explosive and potentially explosive atmospheres is PROHIBITED Installation You must comply with all local and national laws and Euro...

Страница 10: ...cm Minimum distance from combustible rear wall B 50 cm Minimum distance from combustible side wall S 40 cm Minimum distance from combustible material on the front side Fr 150 cm Once you ve determined...

Страница 11: ...f the solutions that can be applied includes storing the furnace that uses wood pellets near the outer wall of the house so that the exhaust fumes are directly released outside Figure 2 4 Some of the...

Страница 12: ...rmful No special conditions are needed for its disposal The user is responsible for the disposal of the remaining components of the packaging The user must follow the proper disposal procedures in acc...

Страница 13: ...ATTENTION Do not let the bag with wooden pellets come into contact with hot parts of the product while you load the fuel ATTENTION Do not remove the protective grid inside the part for loading the pel...

Страница 14: ...ing Main Temp The current value of the room temperature State Functional state of the furnace Main Therm Set room temperature Comb Power Combustion power Heat Power Heating power Time Time Chrono Sche...

Страница 15: ...gnal Block Er47 Auger encoder error auger speed control failed Block Er48 Module error I O 12C Block Er52 Service error This informs that the planned period of operation has been reached after preload...

Страница 16: ...n a distant room It is visible only if the external thermostat is installed while a heating plant that uses it is set up to use an external thermostat Remote Control This menu allows turning the remot...

Страница 17: ...M In the end press P2 in order to activate the program The following is shown on the display Daily Monday ON OFF 09 30 11 1 5 00 00 00 0 0 00 00 00 0 0 This program schedules the furnace to turn on on...

Страница 18: ...up phase the initial checks of the input signals or the probity of safety probes and pressure switches of the furnace are done In this phase the flue gas engine runs at maximum speed while the auger a...

Страница 19: ...hich dispensing of pellets stops and the flue gas engine and the ambient fan operate at maximum capacity in order for the furnace to cool down as soon as possible Minimum duration of the extinguishing...

Страница 20: ...t enters running mode at the end of ignition phase Message Block ignition is shown on the display If an error occurs the system immediately goes into shutdown if P2 is pressed it is possible to immedi...

Страница 21: ...y cable connectors Damage to the display cable connector Contact the service center Er17 Primary air flux meter error Primary air flux meter does not adjust the operation of the furnace The furnace co...

Страница 22: ...t stove or vice versa The smoke extraction duct flue duct and chimney may not be clean or may be nor airtight The point for inserting the flue duct into the chimnex may be flawed The size of theflue d...

Страница 23: ...ctivities is increased in proportion to the intensity of use of the furnace ATTENTION Make sure that the ash is completely cold before you start cleaning the furnace When you make sure the ash is cold...

Страница 24: ...on chamber in the ash container and at the door 7 The inside of the section in which the ash container is located After you ve finished cleaning re assemble all the elements in reverse order from the...

Страница 25: ...22 9 Once in a month unlock the lock mechanism at back side of the stove remove and clean up the chamber lid for collecting dust on the heat exchanger...

Страница 26: ...e heat exchanger using the attached brush and a vacuum cleaner to clean up all the soot and ashes that come out of the heat exchanger After you ve finished cleaning re assemble all the elements in rev...

Страница 27: ...remove all the soot deposited on the stainless steel blade on the engine smoke 5 Vacuum up all the soot deposited inside the base of the engine smoke especially on the left side next to the stovepipe...

Страница 28: ...nd economical way to protect the system from corrosion and to ensure its efficient operation For homes that are not inhabited throughout the year it is recommended to check the stovepipe and funnel at...

Отзывы: