18
Missing
encoder
signal
down
and
then
press P2 for more
than 3 seconds
Er08
Encoder error
Flue gas engine is not
responding
Wait
for
the
furnace to shut
down
and
then
press P2 for more
than 3 seconds
Contact the service center
Flue
gas
engine
operates at a speed that is
different from the set
speed
Er011
Clock error
Problems with the
internal clock
Press and hold
P2 for more than 3
seconds
Check the accuracy of the
preset time
Insufficient capacity of
the internal battery
Check the correctness of
programming in the Chrono
mode
Contact the service center
Er012
Ignition failed
Ignition error
Wait
for
the
furnace to shut
down
and
then
press P2 for more
than 3 seconds
Check the state and
quality of the used pellets
During the ignition
phase adequate temp. of
flue gases is not reached
Check contamination and
draft of the flue drain
Faulty flue gas probe
Contact the service center
Er15
Interruption
of
power supply
Loss of power supply
during furnace operation
Press and hold
P2 for more than 3
seconds
Check to see if the system
and installation are in order
Contact the service center
Er16
Communication
error
between
the
electronics and the
display
Interruption of the
display cable
Press and hold
P2 for more than 3
seconds
Check the cable and
display cable connectors
Damage to the display
cable connector
Contact the service center
Er17
Primary air flux
meter error
Primary air flux meter
does not adjust the
operation of the furnace
The
furnace
continues to run
without adjustment
of primary air.
Turn the furnace
off to reactivate the
air flux meter. Wait
for the furnace to
shut down and then
press P2 for more
than 3 seconds
Check pipe contamination
for primary air inlet
Check contamination and
draft of the flue drain and
funnel
Contact the service center
Er39
Primary air flux
meter
sensor
is
damaged
Faulty sensor
The
furnace
continues to run
without adjustment
of primary air
Contact the service center
Er41
The
minimum
primary air flux is not
reached during the
testing stage
There is an obstacle or
large contamination in the
pipe for primary air inlet
Wait
for
the
furnace to shut
down
and
then
press P2 for more
than 3 seconds
Check and clean the pipe
for primary air inlet
Check contamination and
draft of the flue drain and
funnel
Obstruction of flue gas
drain
Doors not properly
closed during the ignition
phase
Check if the doors close
well
Contact the service center
Er42
Primary air flux is
greater
than
the
maximum permissible
value
Too much air intake
Wait
for
the
furnace to shut
down
and
then
press P2 for more
than 3 seconds
Check the pipe for primary
air inlet
Check contamination and
draft of the flue drain and
funnel
Contact the service center
Description
Possible solution of causes
Содержание LUCA 12