E.g. 4:
To modify the Zone1 attribute to 24 hours and be a silent zone, enter the
programming mode and input: 07+01+300+# ,the buzzer will beeps once after
modification.
E.g. 5:
To modify control panel own wired zone attribute of terminal 2 to NO (Normally open).
Enter the programming and input:05+02+2+#, the buzzer will beeps once after
modification.
E.g. 6:
To modify the system alarm time to 30seconds, enter the programming and input:
12+01+030+#, the buzzer will beeps once after modification.
E.g. 7:
To modify the smart Zone1 to be triggered 3 times every 10 seconds in 10 minutes and
alarm, enter the programming and input: 08+01+10103+#,
The buzzer will beeps once after modification.
E.g. 8:
To clear all wireless zones;
After entering the programming mode, input: 09+00+9+#, after the input, the buzzer beeps once and the modification is
successful.
E.g. 9:
To delete wireless zone1. Into programming on keypad, input: 09+01+9+#
the buzzer will beeps once after modification.
E.g. 10:
To modify User 1 alarm phone number as 13828013204, enter programming and
01+1382# the buzzer will beeps once after modification.
E.g. 11:
To delete user 1 alarm phone number. Enter programming and input: 18+01+# the
buzzer will beeps once after modification.
E.g. 12:
To modify the IP address of the IP module to 192.168.001.201;
After entering the programming mode, input: 34
+
01+19216#, after the input, the buzzer will beep for a long time and
the modification is successful.
E.g. 13:
To change the system date as 02212019, enter programming and input: 39
+
01+0# the buzzer will beeps once after modification.
E.g. 14:
To change system time as: 09:28:00. Enter programming input: 40+01+# the
buzzer will beeps once after modification.
Format: Hours (24hors: 2digits) + minutes (2digits) + seconds (2digits)
Part 3.Zone type and password permission description
1. Zone type and description
Shielded zone
:
This zone is invalid and will not alarm whenever the zone is triggered.
Instant zone
:
Alarm immediately when triggered if zone at arm status
Delay zone
:
If delay zone is triggered after arm successfully, it only alarm at setting
the enter/exit delay time end. If we disarm during delay status, the alarm will be
canceled automatically.
24h zone
:
Regardless of arming or not, while the zones are active, it will alarm as soon as it is triggered