AL-238
PPROGRAMMING GUIDE
18
Function instruction: If this
function is enabled, the master keypad
buzzer will sound every 10 seconds
when the system is under voltage until
the voltage is
restored. If the function is off, it won’t
prompt.
04
0
(
1 digit
)
Reminder when
delay zones’
arming be
triggered
Input Format
:
12+04+X+#
X indicates
:
0 means forbid, while 1
means allow.
Default factory value is 0.
Function instruction
:
If this
function is turned on, it will prompt when
the defense
zone of delay type is
triggered until the defense zone is
restored. If this
function is turned off, it will not prompt.
05
0
(
1 digit
)
Keypad locked
Input Format
:
12+05+X+#
X indicates
:
0 means forbid, 1 means
allow.
Default factory value is 0.Function
instruction
:
If this
function is enabled, the keypad will be
locked automatically when the password
is incorrectly
entered for more than 3 times. To unlock
it, the
control panel needs to be powered off or
wait for 15
minutes to unlock
automatically. If this
function is turned off, the keypad will not
be locked.
06
0
(
1 digit
)
Ac power off/
recovery test
Input Format
:
12+06+X+#
X indicates
:
0 means forbid, 1 means
allow.
Default factory value is 0.Function
instruction
:
If this
function is on, it will be reported to the
center when the system is power off or
restored. If this function is off, do not
report.
07
0
(
1 digit
)
Battery voltage
test
0 means forbid, 1 means allow
PGM
settings
14
01
0
(
1 digit
)
PGM1 attribute
Input Format
:
14+N+X+#
N indicates programming
address 01, 02, which means
control panel comes with attribute PGM1
and PGM 2.
X indicates
:
0
:
Remote control (not
following the output of control panel
status, remote
control only)
1
:
Arming linkage,
disarming disconnects
2
:
Alarm linkage, disarming
disconnects.
3
:
Alarm linkage
(
following
the alarm time of control panel
),
disarming
disconnects.
4
:
Arming linkage (pulse output),
02
1
(
1 digit
)
PGM2 attribute