AL-238
PPROGRAMMING GUIDE
22
04
000.000.000.000
GPRS center IP
address
IP address: Each digit in the IP address
must be entered with 3 digits (such as
192.168.001.002), as long as you enter
12 digits, you do not need to enter the
dot in the middle.
After the input command is correct, the
host will broadcast the previous
configuration information. If you need to
modify it, directly enter the new address
information and press # to save. If you
don’t need to modify it, press the * key to
exit programming;
For example: To set the IP address of
the module to 192.168.1.218;
Enter in the programming state:
34+01+192168001218# is enough;
05
192.168.001.001
Gateway
06
255.255.255.000
Subnet mask
IP module
UDP
settings
35
01
20001
(
5 digits
)
Source UDP port 1
Input format: 35 + N + port number (5
digits) + #;
N represents the programming address
01~06, that is, the source port and
destination port information configuration
of the panel;
The port number is 5 digits, and the
programmable value is: 00000-65535;
02
20002
(
5 digits
)
Source UDP port 2
03
20001
(
5 digits
)
GPRS source UDP
port
04
20001
(
5 digits
)
Destination UDP
port 1
05
03005
(
5 digits
)
Destination UDP
port 2
06
03005
(
5 digits
)
GPRS destination
UDP port
Network
module
DHCP
36
01
0
(
1 digit
)
DHCP on and off
(Note: This function is reserved and not
enabled temporarily)
Input format: 36
+
01+X+#;
X means: 0=prohibited: 1=allowed;
The factory default is 0;
IP heartbeat
detection
37
01
0030
(
4 digits
)
IP1 heartbeat
detection report
time
Input format: 37 + N + reporting time (4
digits) + #;
N means programming address: 01~03,
that is, the heartbeat reporting time
setting of IP center 1, 2 and GPRS
center of the panel;
The reporting time is 4 digits, the unit is
second, the effective programming value
is 0000-9999 seconds, 0000=do not
report;
02
0060
(
4 digits
)
IP2 heartbeat
detection report
time
03
0060
(
4 digits
)
GPRS heartbeat
detection report
time
IP reporting
center
protocol
38
01
1
(
1 digit
)
IP1 reporting center
protocol
Input format: 38
+
N+X+#;
N means programming address: 01~03,
that is, the panel's IP center 1, 2 and
GPRS center report protocol settings;
X means: 1=238P protocol; 2=E5 private
protocol; 3=E5 open protocol;
The default factory setting is 1=238P
protocol
02
1
(
1 digit
)
IP2 reporting center
protocol
03
1
(
1 digit
)
GPRS center
protocol
System
date
39
01
2018.09.28
(
8
digits
)
System date
Input format: 39
+
01+date+#;
The date is 8 digits, the dot in the middle
does not need to be input;
For example: June 17, 2019, enter in the
programming state:39+01+2#;
System time
40
01
00
:
00
:
00
(
6
digits
)
system time
Input format: 40
+
01+time+#;
The time is 6 digits, the middle point
does not need to be input;
Panel
encoding
settings
41
01
0000000000
(
10
digits
)
Panel encoding
settings
Input format: 41
+
01+panel #;
The panel number is 10 digits, it has
been set at the factory, it is not
recommended to change;
Clear
record/resto
re factory
value
44
01
1
(
1 digit
)
Clear records
Input format: 44
+
01+1+#Clear records;
02
1
(
1 digit
)
Restore factory
value
Input format: 44
+
02+1+#;
Perform a factory reset, and then wait for
about 3 seconds (the panel will make a