AL-238
PPROGRAMMING GUIDE
6
2.4.AL-238P connection to wired detector
The AL-238P series control panel can connect up to 8 wired detectors, and supports 4 kinds of zone wiring methods.
The specific connection method is as follows:
1
、
NC wired detector
connection
2
、
NO wired detector
connection
3
、
With 2.2K NO wired
detector connection
4
、
With 2.2K NC wired
detector
connection
Remarks: Description of the default wiring method between the AL-238P panel zone port and the wired detector
The portof the zone (zone 1 to zone 8) is connected to the "NC signal" of the detector by default;
Please use a wire to plug-in the zone terminals that do not need to be connected to the detector, or close it through keypad
programming. For programming, please refer to the "command 05" in the programming table of the manual;
2.2K
EOL resistor
2.2K
EOL resistor