AE–1800 Instruction Manual
User-Level Troubleshooting
5 . 5 . B l a n k
M e ss a g e
S c r ee n
The following description of the symptom assumes that your NAVTEX receiver was
properly working for some time after initial installation time.
Symptom
Suggested Solution
The NAVTEX receiver can be
turned on but the message screen
remains blank.
1. Check to be sure that the power source
voltage is within the 11–36V range.
2. Repeatedly press
to check if the
normal brightness returns.
3. Suspect that the LCD module or Main
PCB has become defective. Ask your
dealer/ qualified service engineer to check
the related connections to/ from the
module and the Main PCB, and replace
the module and / or the PCB.
4. Suspect that the Main PCB has become
defective. Ask your dealer/qualified
engineer first to check the related
connections to/from the PCB, and to
replace the PCB, if necessary.
5 . 6 . U n c o n tr o l l a b l e S c r ee n B r i g h tn e s s
The following description of the symptom assumes that your NAVTEX receiver was
properly working for some time after initial installation time.
Symptom
Suggested Solution
The NAVTEX receiver can be
turned on but the message screen
brightness cannot be controlled.
The brightness level does not change
by pressing
.
1. Check to be sure that the power source
voltage is within the 11–36V range.
2. Suspect that the Main PCB has become
defective. Ask your dealer/qualified
engineer to check the wiring harnesses
to/from the PCB first and to replace the
PCB, if necessary.
5 . 7 . N o B e ep fr o m K e yp r e s s
The following description of the symptom assumes that your NAVTEX receiver was
properly working for some time after initial installation time.
Symptom
Suggested Solution
No keypress beep is heard.
1. Check if the keypress beep function is
disabled. Refer to paragraph 4.7 for
instructions
.
2. Ask your dealer/qualified engineer to
check the related wiring to/from the
keypress buzzer
.