![ALDEN AE-1800 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/alden/ae-1800/ae-1800_instruction-manual_2892872054.webp)
AE–1800 Instruction Manual
Customizing Operation via Menu System
4 . 1 2 . 3. S e l e c ti n g C o m m un i c a t i on s P ro t o c ol s
The following communications protocols are initially assigned to the three output ports
described in paragraph 4.12.
・
IEC 61162–1 (NMEA–0183 Ver. 2.0 & greater):
RS– 422
Port
・
Asynchronous non–handshaking:
RS– 232
Port and
I / O DATA
Port
Of the three ports, only the
I / O DATA
port can select either the IEC 61162–1 or the
asynchronous non–handshaking transfer mode. If your application using that port
requires the IEC 61162–1 as its protocol, follow the steps given below.
NOTE: If you wish to connect a serial printer other than the
PR–900
to the
RS–232C
or the
I / O DATA
port, be sure to turn off its hardware flow control and set it to “X–ON/X–OFF,” if
available, or an erratic printout can result.
(1) Highlight option “
2:SELECT PROTOCOLS
” on the
SET OUTPUT PORTS
submenu,
and press
. This turns on another submenu for selection of the protocols, as
illustrated below.
Figure 4-29 Accessing Submenu for Selection of Protocols for
I / O DATA
Port
(2) To change the protocol
for the
I / O DATA
port to
the IEC 61162–1, press
, highlighting option
I E C 61162
, as shown
below.
Figure 4-30 Selecting Protocol for
I / O DATA
Port
(3) Press
to complete
the selection.
(4) Press
to return to the previous submenu or
to return to the first receiver
text page.
Protocols are selectable for this port only.
S Y S T E M M E N U
1:
MAKE DISPLAY SETTINGS
2: SELECT 2ND RECEIVER FREQUENCIES
3: TURN ON / OFF KEYPRESS BEEP
4: MAKE SEL / REJ SETTINGS
5: SEARCH FOR STORED MESSAGES
6. SELECT OUTPUT MESSAGES
7. SET OUTPUT PORTS
8. START SELF–DIAGNOSTIC TESTS
9: TURN ON / OFF MESSAGE ALARM
0. RESET TO FACTORY DEFAULTS
7: SET OUTPUT PORTS
1: SET PORTS ON / OFF
2: SELECT PROTOCOLS
3: SET BIT FORMAT & RATE
2: SELECT PROTOCOLS
1: RS– 232C I EC61162 N O N E
( A S C I I )
2: RS– 422
I EC61162
N O N E
( A S C I I )
3: I / O DATA
I I EC61162
N O N E ( A S C I I )
2: SELECT PROTOCOLS
1: RS– 232C I EC61162 N O N E
( A S C I I )
2: RS– 422
I EC61162
N O N E
( A S C I I )
3: I / O DATA
I i
I EC61162
i N O N E
( A S C I I )