Distributed Spanning Tree Commands
page 16-158
OmniSwitch 6250 CLI Reference Guide
November 2009
-> show spantree 1x1 1 ports configured
Spanning Tree Port Admin Configuration for Vlan 1
Port Adm Man. Config Adm Adm Aut Rstr Rstr Role/ OS8800 PVST+
Port Pri St. Mode Cost Cnx Edg Edg Tcn Root Guard 10G Opt Cfg Stat
-----+----+----+----+-------+----+----+-----+----+---------+--------+---------
1/1 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/2 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/3 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/4 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/5 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/6 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/7 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/8 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/9 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/10 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/11 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/12 7 ENA No 0 AUT No Yes No No DIS AUT OFF
-> show spantree 1x1 10-13 ports configured
Spanning Tree Port Admin Configuration for Vlan 10
Port Adm Man. Config Adm Adm Aut Rstr Rstr Role/ OS8800 PVST+
Port Pri St. Mode Cost Cnx Edg Edg Tcn Root Guard 10G Opt Cfg Stat
-----+----+----+----+-------+----+----+-----+----+---------+--------+---------
1/46 7 ENA No 0 AUT No Yes No No DIS AUT OFF
Spanning Tree Port Admin Configuration for Vlan 11
Port Adm Man. Config Adm Adm Aut Rstr Rstr Role/ OS8800 PVST+
Port Pri St. Mode Cost Cnx Edg Edg Tcn Root Guard 10G Opt Cfg Stat
-----+----+----+----+-------+----+----+-----+----+---------+--------+---------
1/36 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/37 7 ENA No 0 AUT No Yes No No DIS AUT OFF
Spanning Tree Port Admin Configuration for Vlan 12
Port Adm Man. Config Adm Adm Aut Rstr Rstr Role/ OS8800 PVST+
Port Pri St. Mode Cost Cnx Edg Edg Tcn Root Guard 10G Opt Cfg Stat
-----+----+----+----+-------+----+----+----+----+----------+--------+---------
1/42 7 ENA No 0 AUT No Yes No No DIS AUT OFF
1/43 7 ENA No 0 AUT No Yes No No DIS AUT OFF
Spanning Tree Port Admin Configuration for Vlan 13
Port Adm Man. Config Adm Adm Aut Rstr Rstr Role/ OS8800 PVST+
Port Pri St. Mode Cost Cnx Edg Edg Tcn Root Guard 10G Opt Cfg Stat
-----+----+----+----+-------+----+----+----+----+----------+--------+---------
1/38 7 ENA No 0 AUT No Yes No No DIS AUT OFF
output definitions
Port
The slot number for the module and the physical port number or a logi-
cal port. If the slot number is 0, then the port number refers to a link
aggregate logical port number (e.g., 0/31).
Port Pri
The Spanning Tree priority for the port (0–15). The lower the number,
the higher the priority. Configured through the
command.
Adm St
The Spanning Tree administrative status of the port:
enabled
or
dis-
abled
. Configured through the
disable Spanning Tree on a port.
Содержание OmniSwitch 6250
Страница 1: ...Part No 060305 10 Rev A November 2009 OmniSwitch 6250 CLI Reference Guide www alcatel lucent com...
Страница 32: ...Technical Support About This Guide page xxxii OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 140: ...Power over Ethernet PoE Commands page 4 18 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 212: ...Session Management Commands page 6 52 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 270: ...File Management Commands page 7 58 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 280: ...Web Management Commands page 8 10 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 328: ...SNMP Commands page 10 32 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 338: ...DNS Commands page 11 10 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 392: ...Link Aggregation Commands page 12 54 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 440: ...802 1Q Commands page 15 8 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 616: ...Distributed Spanning Tree Commands page 16 176 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 628: ...Loopback Detection Commands page 17 12 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 768: ...Ethernet Port Commands page 20 96 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 826: ...VLAN Management Commands page 22 26 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 968: ...Ethernet OAM Commands page 25 56 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 1014: ...LINK OAM Commands page 26 46 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 1036: ...UDLD Commands page 27 22 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 1048: ...Port Mapping Commands page 28 12 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 1256: ...IPv6 Commands page 30 90 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 1276: ...RDP Commands page 31 20 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 1285: ...DHCP Relay Commands OmniSwitch 6250 CLI Reference Guide November 2009 page 32 9 MIB Objects iphelperStatTable iphelperForwOption...
Страница 1287: ...DHCP Relay Commands OmniSwitch 6250 CLI Reference Guide November 2009 page 32 11 MIB Objects iphelperStatTable iphelperForwDelay...
Страница 1289: ...DHCP Relay Commands OmniSwitch 6250 CLI Reference Guide November 2009 page 32 13 MIB Objects iphelperStatTable iphelperMaxHops...
Страница 1291: ...DHCP Relay Commands OmniSwitch 6250 CLI Reference Guide November 2009 page 32 15 MIB Objects iphelperAgentInformation...
Страница 1372: ...RIP Commands page 33 32 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 1388: ...Port Mirroring and Monitoring Commands page 34 16 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 1659: ...QoS Policy Commands OmniSwitch CLI Reference Guide November 2009 page 39 163 MIB Objects alaQoSClassifyTable alaQoSClassify8021p...
Страница 1702: ...QoS Policy Commands page 39 206 OmniSwitch CLI Reference Guide November 2009...
Страница 1718: ...Policy Server Commands page 40 16 OmniSwitch 6250 CLI Reference Guide November 2009...
Страница 2018: ...Index Index 6 OmniSwitch 6250 CLI Reference Guide November 2009...