Description
Values
Min
Def
Max.
A
B
C
D
E
P8
Probe to be displayed (as per parameter P4) (Page 8)
0
=visualization of all the probes in sequence;
1
=Probe 1;
2
=Probe 2;
3
=Probe 3 (2)
1
1
3
No No Yes Yes Yes
P9
Selection of probe type
0
=NTC;
1
=PTC (Page 8)
0
0
1
Yes Yes Yes No No
P10
Configuring digital input 1 (Page 9)
0
= Off
1
=Door contact
2
=External alarm
3
=Severe external alarm
4
=Slave defrost
5
=Act. modo ECO
6
=Act. Fast Freezing (If C9
¹
0)
7
= Low pressure switch (2)
0
0
7
No No Yes Yes Yes
P11
Configuring digital input 2 (Page 9)
0
= Off
1
=Door contact
2
=External alarm
3
=Severe external alarm
4
=Slave defrost
5
=Act. ECO mode
6
=Act. Fast Freezing (If C9
¹
0)
0
0
6
No No Yes Yes Yes
P12
Digital input polarity 1 (Page 9)
0
=Energised on closed contact,
1
=Energised on open contact
0
0
1
No No Yes Yes Yes
P13
Digital input polarity 2 (Page 9)
0
=Energised on closed contact,
1
=Energised on open contact
0
0
1
No No Yes Yes Yes
P14
Maximum start-up time after pump down (Page16)
(sec.)
1
10
999
No No No No Yes
P15
Maximum pump down time (Page16)
(sec. x 10)
1
30
999
No No No No Yes
EP
Exit Level 1
Level 2
Description
Values
Min
Def
Max.
A
B
C
D
E
r1
Clock configuration: HOUR (Page 9)
(h.)
0
0
23
No No
(3)
Yes No Yes
r2
Clock configuration: MINUTES (Page 9)
(min.)
0
0
59
No No
(3)
Yes No Yes
EP
Exit Level 1
Description
Values
Min
Def
Max.
A
B
C
D
E
L5
Access code (Password) (Page 9)
0
-
99
Yes Yes Yes Yes Yes
PU
Program version (Information)
-
Yes Yes Yes Yes Yes
Pr
Program revision (Information)
-
Yes Yes Yes Yes Yes
EP
Exit Level 1
Level 2
Level 2
Level 1.- Real Time Clock Parameters
Level 1.-
(tid)
Access control and information
(1): Second defrost is available only on units with 4 relays.
(2): Only available on
AKO-D14412-RC
and
AKO-D14423-RC
(3)
Not available in
AKO-D14112, AKO-D14123-2
28
A:
Available in
AKO-D14012 / D14023 / D14023C / D14024
D:
Available in
AKO-D14212 / D14220 / D14223 / D14312 / D14320 / D14323 / D14323-C / D10223 / D10323
C:
Available in
AKO-D14112 / D14123-2 / D14123-2-RC
E:
Available in
AKO-D14412-RC, AKO-D14423-RC
B:
Available in
AKO-D14120 / D14123 / D14124 / D14125 / D10123