SET
ESC
ECO relay
*
active
COOL relay active (P0=0)*
Standby
active
Keyboard
Fast freezing
mode*
AUX relay active*
*Depending on model
Flashing
lights indicate that the function in question should be activated by temperature, but is not due to a conflicting
timing or protection parameter.
RES relay active (P0=1)
(P6=3)
or lights on
*
DEF relay energised*
Program
Mode
FAN relay
*
active
Display
2.1.- Keypad functions
Controllers
Only models with 4 keys
Press for 5 seconds to start/stop Fast Freezing mode
(rapid cooling).
In the programming menu, exit without saving parameter,
return to previous level or exit programming.
Press for 5 seconds, allows changing the set point (SP).
Pressing for 10 seconds goes to the programming menu.
In the programming menu, go to the level displayed or accept
the new value while setting a parameter.
Press for 5 seconds to start/stop Fast Freezing mode.
In the programming menu, allows you to scroll through
the various levels or, during the setting of a parameter, to
change the value.
Press for 5 seconds
m
, activates standby mode.
Pressing for two seconds, the device returns to normal.
In Standby mode, the equipment performs no actions and
only the indicator is displayed on the screen..
In programming menu, allows you to scroll through the
various levels or, during the setting of a parameter, to change
the value.
SET
ESC
IMPORTANT:
If you have configured the access code function as a key lock (P2=2) when you initiate any function
(defrost, fast freezing, access to programming, etc.) you will be prompted to enter the access code programmed into
L5. If the code entered is not correct, the unit will display the temperature without opening the requested function.
2.- Description
Thermometers
SET
Press for 5 seconds to activate Standby mode; press for 2 seconds to return the equipment to normal mode. In
Standby mode, the equipment performs no actions and only the
m
indicator is displayed on the screen .
Press for 10 seconds to go to the programming menu.
Press for 5 seconds in the programming menu to access the level displayed on the screen or, during the setting of a
parameter, accepts the new value.
In the programming menu, a short press allows you to scroll through the various levels or, during the setting of a parameter, to
increment the value. When upper limit is reached, it will start again from the lower limit.
4
Switches
Extended panel version
1 Key
3 Keys
4 Keys
SET
SET
SET
ESC