27
Model No: AC-F30HG
Version 1.0
Note:
The TEST” button on the cover no is specially for testing the air conditioner.
When pressing it, the air conditioner will be forced to operate or stop. Do not press it when air
conditioner is in normal operation.
For the following items, take special care during construction and check after
installation is finished.
Items to check
If not properly done, what is likely to happen
Is the indoor unit fixed firmly?
The unit may drop, vibrate or make noise.
Is the gas leak test finished?
It may result in insufficient cooling.
Is the unit fully insulated?
Condensate water may drip.
Does drainage flow smoothly?
Condensate water may drip.
Does the power supply voltage correspond to that
shown on the nameplate
The unit may malfunction or the components burn out.
Are wiring and piping correct?
The unit may malfunction or the components burn out.
Is the unit safely grounded?
Risk of electric leakage.
Is wiring size according to specifications?
The unit may malfunction or the components burn out.
Is something blocking the air outlet or intake of either
the indoor or outdoor units?
It may result insufficient cooling.
Have records of refrigerant piping length and
additional refrigerant charge been made?
Volume of refrigerant charge in the system is not clear.
Note to the installer
Be sure to instruct the customer how to operate the system and show him/her the attached operation
manual.
Все каталоги и инструкции здесь:
http
:
//splitoff.ru/tehn-doc.html
Содержание AC-F30HG
Страница 1: ...Air Conditional Service Manual http splitoff ru tehn doc html...
Страница 2: ...Model No AC F30HG Version 1 0 2 Model AC F30HG http splitoff ru tehn doc html...
Страница 11: ...11 Model No AC F30HG Version 1 0 OUTDOOR UNIT http splitoff ru tehn doc html...
Страница 28: ...28 Model No AC F30HG Version 1 0 CIRCUIT DIAGRAM http splitoff ru tehn doc html...