18
Model No: AC-F30HG
Version 1.0
Note
The incline of attached drain hose should be 75mm or less, so that the drainage socket does not have to
stand additional force.
If converging multiple drainage pipes, install according to the procedure shown below.
Select converging drainage pipes whose gauge is suitable for the operating capacity of the unit.
2 After finishing installation, check if drainage water flows smoothly.
a. Add approximately 600 cc of water to the drainage trough through air outlet or inspection hole
slowly and check drainage flow.
b. When electric wiring is finished, check drainage flow during cooling operation.
Method of adding water
Warning:
Before obtaining access to terminals, all supply circuits must be disconnected.