Indications
31 (48)
Installation manual Remotus Jupiter 10BD, Era 4/6/8B FSK16 Version: B0 Document-ID: 954045-000 EN Author: SH
9.2
Transmitter indications
9.2.1 Status indicator
If the transmitter under start up (if not PIN locked) or operation detects a fault in any of the transmitters
mitter is shut down.
BAT.
INDICATIONS
EXPLANATIONS
Green flashing
OK, normal operation
Yellow quick flashing
Battery voltage low <3.5 V
Yellow continuous, during operating
Battery empty. Transmitter will shut-off within 10s
Yellow continuous, at start-up
Configuration mode
Red continuous, at start-up
PIN locked
Red continuous, during operation
Hardware fault
9.2.2 Display indications
These default symbols can appear on the display depending on the configuration.
For configuration see RX16X configuration tool manual.
1. Radio signal / MC / Low/High power
2. Channel indicator, up to 3 digits
(if the 433MHz region setting is “Other” an “E” is displayed after the channel number)
3. Selection (SHIFT Era 8B 9/10 Buttons) (1/2 selection 10BD)
4. Text field (crane id etc.)
5. Battery level
6. Dig. In 1 & 2 (shows if active)
7. Overload warning
8. Weight load graph (full-scale=max load)
9. Weight, up to 5 digits
10. Weight unit (kg,t or lb)
Crane 1
14.1kg
1 2
T1 T2
A B
1
3 4
5
6
7
10
8
9
2
9.2.2.1 Radio signal quality
No radio link established
Weak signal Good signal
Strong signal Very strong signal
At low power mode the first bar is narrower.
MC on is indicated by a line beneath the radio signal symbol, example
.
9.2.2.2
Text field (crane id etc.) (option)
This text is configured in the receiver (8 characters) using the RX161 configuration tool.
9.2.2.3 Battery level
Battery empty 25%
50%
75%
100% (fully charged)
9.2.2.4 Weight / Graph / Overload (option)
The weight is shown with the unit symbol kg, t or lb. depending on the receiver configuration.
The bar graph displays the weight load. Full scale= maximum load. The graph is only shown if a maxi-
mum weight limit is configured in the receiver.
This
symbol appears if the load on the crane reaches the weight limit (overload).
Refer to the RX16X configuration tool.
9.2.2.5 Selection (only SHIFT Era 8B 9/10 BUTTONS, 10BD)
Shows which selections that currently are active.