Ultrasonic Fuel Level Sensor Manual
Updated until firmware 405p & 1.0.3816
- 36 -
Invasive Specific Specification
Mounting Pattern
Standard SAE 5 mounting hole for easy fit.
Minimum Tank Depth
Not suitable for tank liquid depths less than 200mm
Measurement Method
Acoustic sonic measurement
Tank Depth
0
–2000 mm (6.5 ft)
Accuracy Distance
0
–2000 mm (6.5 ft) at 2 mm accuracy
Full Scale Accuracy
+/- 2%-5% Full-Scale Accuracy
Mounting
SAE 5 stud mounting pattern with gasket, seal and screws
(top mount only)
Tank Type Style
Metal and plastic with nonlinear capacity, with thickness less
than 8mm
Operating Temperature
4°C to 65°C
Electrical
Power Supply
Operates from 12 VDC External Power Suppler (included)
Current Draw
25 mA with 5 V gauge output
Ignition Protected
ISO 8846
Fire Resistance
Tested to ABYC, US Coast guard and ISO10088
Output types:
Analogue 10-180, 10-300, 240-33 ohm gauges and 0-5volt