Suburban DynaPack S & H Series Owner's Manual 06/2020 Rev.2
8
The Dynapack unit is approved for indoor installation only and must be installed with one of the factory supplied wall sleeves. The unit is
intended to be installed in a closet or equipment room. The unit is certified for 0” clearance to the cabinet sides, cabinet back and the first
3 feet of the supply duct. However for accessibility reasons it is recommended to maintain at least 1” clearance on the sides for proper
installation and servicing. For closet installations allow 4” clearance from the unit door panels to the closet door. For equipment room
installations allow 24”clearance from the unit door panels to a wall for servicing.
The wall sleeve and grille is intended to be installed flush with the exterior wall. The unit, wall sleeve, and grille are required to be installed
certain distances from adjacent doors, operable windows and shrubbery. See figure 11 at the end of this chapter..
CAUTION
The unit must be installed level front to back and side to side. Adjust front leveling legs as necessary.
B: WALL SLEEVE AND GRILLE INSTALLATION
TOP VIEW
4" MIN. TO DOOR
1" RECOMMENDED
1" RECOMMENDED
CONTROL WIRES
ELECTRICAL POWER
Figure 6
Refer to installation instructions included with the wall sleeve kit for guidance in
assembling and installing the wall sleeve and grille.
CAUTION
The sleeve will support the back of the unit.
C: FLUE GAS EXHAUST TUBE INSTALLATION (H SERIES MODELS)
All H Series DynaPack units are shipped with the Flue Gas Exhaust Tube disconnected. Locate the Flue Gas Exhaust Tube inside the
unit cabinet and the clamps and couplers in the accessory bag. Connect the Flue Gas Exhaust Tube using the rubber coupler as shown
in the photo below.
The unit is shipped with the Flue Gas Tube disconnected
Connect the Flue Gas Tube (A) as shown. Ensure the clamp (shipped
in the parts bag) is positioned as shown (B)