13-20
CONTROL SYSTEM
SM DLF 1-A.1 GB
13.2.3
Unit Operation in Test Mode
In test mode, the unit will operate in fixed settings according to the indoor fan speed setting:
Indoor FAN Speed Setting
Unit Setting
Low
Minimum Capacity Setting
Turbo
Nominal Capacity Setting
Auto
Maximum Capacity Setting
During test mode, protections are disabled, except for stop compressor status.
13.3 Parameters
13.3.1
General Parameters for all models
#
Name
Values(Factory Setting)
1
CVStep
0
2
Cool2Heat
3
3
Heat2Cool
3
4
ICTDef1
8
5
ICTDef2
6
6
ICTDef3
4
7
ICTDef4
2
8
ICTDef5
0
9
ICTDef6
-2
10
ICTDeltaDef1
1
11
ICTDeltaDef2
-1
12
ICTDeltaOH1
-1
13
ICTDeltaOH2
1
14
FLTRTime
1023
15
PITconst
30
16
STARTTIMETURBOH
10
17
IFANOffTimeDry
3
18
IFANOnTimeDry
1
19
ICTLowLimitDry
10
20
ICTHighLimitDry
12
21
ExtraNLOADDry
20
22
IFANMAXTimeH
150
23
IFANOffTimeH
4
24
IFANOnTimeH
3
25
IFANTimeHeat2STBY
30
26
MAXTURBOTIMEF
30
27
MAXTURBOTIMEC
30
28
MAXTURBOTIMEH
30
Содержание Multi Split DUO 50 DCI
Страница 14: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit DCI 25 35 50 4 3 Outdoor Unit DCI 60...
Страница 15: ...4 3 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 4 Outdoor Unit DCI 72Z...
Страница 47: ...7 4 SOUND LEVEL CHARACTERISTICS SM DLF 1 A 1 GB DCI 50 Cooling DCI 50 Heating DCI 60 Cooling DCI 60 Heating...
Страница 48: ...7 5 SOUND LEVEL CHARACTERISTICS SM DLF 1 A 1 GB DCI 72Z Cooling DCI 72Z Heating...
Страница 93: ...15 5 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 5 Indoor Unit DLF 60 72 DCI E F G D E D D E D...
Страница 96: ...15 8 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 8 Outdoor Unit DCI 50...
Страница 98: ...15 10 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 10 Outdoor Unit DCI 60...
Страница 100: ...15 12 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 12 Outdoor Unit DCI 72Z...