13-15
CONTROL SYSTEM
SM DLF 1-A.1 GB
13.1.24 Self
Test
Jumper(J1))
●
Jumper for production line only, never install jumper on site!
13.1.25
DIP Switch and Jumper Settings
●
CK - Dip switch default setting for each model
1
2
3
4
5
6
7
8
J2
J3
J6
J7
J8
J9
J12
J13
2.5 KW
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
3.5 KW
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
5.0 KW
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
6.0 KW
ON
ON
OFF
ON
OFF
OFF
ON
OFF
7.0 KW
ON
ON
OFF
OFF
ON
OFF
ON
OFF
●
DLF - Dip switch default setting for each model
1
2
3
4
5
6
7*
8**
J2
J3
J5
J7
J8
J9
J10
J12
2.5 KW
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
3.5 KW
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
5.0 KW
ON
OFF
OFF
ON
ON
OFF
ON
OFF
6.0 KW
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
7.0 KW
ON
ON
OFF
ON
OFF
OFF
ON
OFF
*Water pump and float switch setting
In case of vertical installation, change dipswitch 7 to OFF position to cancel their operation.
**High external static pressure
There is an option of increasing the airflow if the ESP (external static pressure) is higher than
planned. To increase the speed change dipswitch 8 to ON position.
● Compensation setting (Factory setting)
This setting activates the compensation to the return air temperature in heating mode. For indoor unit
like cassette, the DIP switch J2 should be ON.
Compensation
J2
Activated(factory setting)
ON
Deactivated
OFF
● Unit model setting (Factory setting)
The unit model setting should be in accordance with the unit model on the nameplate. The unit
operating parameters will be improper with wrong settings.
Unit model(Capacity)
J3
J6
J7
J8
2.5kW model
OFF
OFF
OFF
OFF
3.5kW model
OFF
OFF
ON
OFF
5.0kW model
ON
OFF
OFF
OFF
6.0kW model
ON
OFF
ON
OFF
7.0kW model
ON
OFF
OFF
ON
MODEL
DIP
MODEL
DIP
J
J
Содержание Multi Split DUO 50 DCI
Страница 14: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit DCI 25 35 50 4 3 Outdoor Unit DCI 60...
Страница 15: ...4 3 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 4 Outdoor Unit DCI 72Z...
Страница 47: ...7 4 SOUND LEVEL CHARACTERISTICS SM DLF 1 A 1 GB DCI 50 Cooling DCI 50 Heating DCI 60 Cooling DCI 60 Heating...
Страница 48: ...7 5 SOUND LEVEL CHARACTERISTICS SM DLF 1 A 1 GB DCI 72Z Cooling DCI 72Z Heating...
Страница 93: ...15 5 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 5 Indoor Unit DLF 60 72 DCI E F G D E D D E D...
Страница 96: ...15 8 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 8 Outdoor Unit DCI 50...
Страница 98: ...15 10 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 10 Outdoor Unit DCI 60...