TROUBLESHOOTING
SM DL
F 1
-A.1 GB
No
Fault Name
Fault Description
Corrective Action
31
Operation conditions are
exceeded
System is performing out
of its outdoor condition
limitations:
Cooling: >46°C , <-11°C.
Heating: >30°C , <-18°C.
Indication only, no action.
Check if indeed the conditions are
exceeded. If not, check OAT thermistor, if
OK, check no obstructions to outdoor air
path.
13.4.3
Fault Code for Indoor unit
Note:
Indoor unit diagnostics can be viewed by the outdoor unit display board
(13.4
).
The below procedure is for viewing the indoor unit codes via the indoor unit led display.
Pressing Mode button for more than 5 seconds will activate diagnostic mode by the acknowledgment
of 3 short beeps and lighting of COOL and HEAT LED’s.
When Indoor diagnostics is displayed, all four LED’s (STBY, Operate, Filter, TMR) are on.
Entering diagnostics in STBY mode allows only viewing of status (fault-display).
In diagnostic mode, system problems / information will be indicated by blinking of Heat & Cool LED’s.
The coding method will be as follows:
Heat led will blink 5 times in 5 seconds, and then will be shut off for the next 5 seconds. Cool Led will
blink during the same 5 seconds according to the following table:
No
Fault Name
5
4
3
2
1
1
ICT is disconnected
0
0
0
0
1
2
ICT is shorted
0
0
0
1
0
3
RAT is disconnected
0
0
0
1
1
4
is shorted
0
0
1
0
0
5
Reserved
0
0
1
0
1
6
ICTE Shorted/Disconnected
0
0
1
1
0
7
==J'
0
0
1
1
1
8
No Communication
0
1
0
0
0
9
No Encoder
0
1
0
0
1
10
Reserved
0
1
0
1
0
11
Outdoor Unit Fault
0
1
0
1
0
…
Reserved
17
Defrost protection
1
0
0
0
1
18
Deicing Protection
1
0
0
1
0
19
Outdoor Unit Protection
1
0
0
1
1
20
Indoor Coil HP Protection
1
0
1
0
0
21
<"%Q
1
0
1
0
1
…
Reserved
24
EEPROM Not Updated
1
1
0
0
0
25
Bad EEPROM
1
1
0
0
1
26
Bad Communication
1
1
0
1
0
27
Using EEPROM data
1
1
0
1
1
28
Model A
1
1
1
0
0
29
Model B
1
1
1
0
1
30
Model C
1
1
1
1
0
31
Model D
1
1
1
1
1
1 - ON, 0 - OFF
Only one code is shown. Order of priority is lower to the higher number. Diagnostics is continuously
ON as long power is on.
Содержание DLF 18 DCI
Страница 11: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit YBDE 018 024...
Страница 31: ...12 3 CONTROL SYSTEM SM DLF 1 A 1 GB 12 2 2 Controller overview 12 2 2 1 Main Controller Indoor Unit DLF 18 24...
Страница 65: ...12 37 CONTROL SYSTEM SM DL A 1 GB 12 9 5 Remote Control RC 8 Reset Operation...
Страница 69: ...12 41 CONTROL SYSTEM SM DLF 1 A 1 GB 12 11 7 Segment Legend 7 7 segments lege end...
Страница 91: ...14 2 SM DLF 1 A 1 GB EXPLODED VIEWS AND SPARE PARTS LISTS 14 2 Indoor Unit DLF 18 DCI...
Страница 95: ...14 6 SM DLF 1 A 1 GB EXPLODED VIEWS AND SPARE PARTS LISTS 14 4 Indoor Unit DLF 24 DCI E F G D E D D E D...
Страница 96: ...14 7 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 14 5 Indoor Unit DLF 24 DCI...