SM DL
F
1
-A.
1
GB
12-1
K
12.4.9
Indoor Units Operation when Indoor Unit Mode is Different than
Outdoor Unit Mode
x
Open louvers according to user selection.
x
Indoor fan is forced to OFF.
x
Indoor unit led is blinking
12.4.10
Indoor Unit Dry Contact
Status
Function
Contact = Open
Contact = Short
J9 = Open
Clock
See below
See below
J9 = Short
Presence Detector Connection
No action - normal operation
Forced to STBY
The Clock is activated according to the following table:
A/C STATE
(before clock is
changed)
CLOCK STATE
(before clock is changed)
CLOCK ACTION (clock
is changed)
A/C NEW STATE
(after clock is
changed)
ON
1
0
OFF
ON
0
1
ON
OFF
0
1
ON
OFF
1
0
OFF
12.4.11
On Unit Controls and Indicators
STAND BY
INDICATOR
Lights up when the Air Conditioner is connected to power and ready to receive
the R/C commands
OPERATION
INDICATOR
Lights up during operation.
Blinks for 300 mSec to announce that R/C infrared signal has been received and
stored.
Blinks continuously during protections (according to the relevant spec section).
TIMER INDICATOR
Lights up during Timer and Sleep operation.
FILTER INDICATOR
Lights up after fix period of operation to indicate that filter needs to be cleaned.
COOLING
INDICATOR
Lights up when system is switched to Cool Mode by using the Mode Switch on the
unit.
HEATING
INDICATOR
Lights up when system is switched Heat Mode by using the Mode Switch on the
unit.
Mode SWITCH
(COOL/HEAT/OFF)
Every short pressing , the next operation mode is selected, in this order :
SB Cool Mode Heat Mode SB …
In long pressing system enters diagnostic mode.
CONTROL SYSTEM
Содержание DLF 18 DCI
Страница 11: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit YBDE 018 024...
Страница 31: ...12 3 CONTROL SYSTEM SM DLF 1 A 1 GB 12 2 2 Controller overview 12 2 2 1 Main Controller Indoor Unit DLF 18 24...
Страница 65: ...12 37 CONTROL SYSTEM SM DL A 1 GB 12 9 5 Remote Control RC 8 Reset Operation...
Страница 69: ...12 41 CONTROL SYSTEM SM DLF 1 A 1 GB 12 11 7 Segment Legend 7 7 segments lege end...
Страница 91: ...14 2 SM DLF 1 A 1 GB EXPLODED VIEWS AND SPARE PARTS LISTS 14 2 Indoor Unit DLF 18 DCI...
Страница 95: ...14 6 SM DLF 1 A 1 GB EXPLODED VIEWS AND SPARE PARTS LISTS 14 4 Indoor Unit DLF 24 DCI E F G D E D D E D...
Страница 96: ...14 7 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 14 5 Indoor Unit DLF 24 DCI...