PRODUCT DATA SHEET
2.1 DL
F
18 DCI
Model Indoor Unit
AWSI-DL
F
018 –N11
Model Outdoor Unit
AWAU-YBDE018-H11
Installation Method
DUCTED
Characteristics
Units
Cooling
Heating
Average Warmer
Pdesign
kW
5.0
4.8
4.8
SEER / SCOP
(1)
W/W
5.
4
3.9
4.
3
Energy efficiency class
A
A
A+
Annual energy consumption
kWh
808
2
549
1
488
Tbiv
o
C
N/A
-3
6
Tol
o
C
N/A
-15
-15
Capacity Range
(1)
(min÷max)
kW
1.5
÷5.
8
1.
3
÷
6.8
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
20
INDOOR
Fan type & quantity
Centrifugal x
2
Fan speeds
H/M/L
RPM
1110
/
980
/
860
Air flow
(2)
H/M/L
m
3
/hr
710
/
600
/
540
External static pressure
Min-Max
Pa
0
-
4
0
Sound power level
(3)
H/M/L
dB(A)
54
/5
1
/
48
Sound pressure level
(4)
H/M/L
dB(A)
35
/
32
/
29
Moisture removal
l/hr
1.
8
Condensate drain tube I.D
mm
19
Dimensions
WxHxD
mm
7
5
0x
630
x
200
Weight
kg
2
1
Package dimensions
WxHxD
mm
890
x
71
0
x
243
Packaged weight
kg
2
3
Units per pallet
units
14
Stacking height
units
7
OUTDOOR
Refrigerant control
EEV
Compressor type, model
Twin Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
RPM
200 – 750 (continuous)
Air flow
Max.
m
3
/hr
2500
Sound power level
Nom.
dB(A)
65
Sound pressure level
Nom.
dB(A)
53
Dimensions
WxHxD
mm
900x700x340
Weight
kg
56
Package dimensions
WxHxD
mm
985x730x435
Packaged weight
kg
58.5
Units per pallet
Units
6 units per pallet
Stacking height
units
2 levels
Refrigerant type
R410A
Refrigerant charge (standard connecting tubing
length)
kg(7.5m)
1.55
Additional charge per 1 meter
gr / 1m
7.5m < 0gr < 15m < 35gr per 1m < 30m
Connections between
units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
1/2"(12.7)
Max. tubing length
m.
30
Max. height difference
m.
15
Operation control type
Remote control
Heating elements
kW
Others
(1) Rating conditions in accordance with EN14825 and EN14511 (for ducted units).
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1.4 meter distance from unit.
2. PRODUCT
DATA SHEET
Содержание DLF 18 DCI
Страница 11: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit YBDE 018 024...
Страница 31: ...12 3 CONTROL SYSTEM SM DLF 1 A 1 GB 12 2 2 Controller overview 12 2 2 1 Main Controller Indoor Unit DLF 18 24...
Страница 65: ...12 37 CONTROL SYSTEM SM DL A 1 GB 12 9 5 Remote Control RC 8 Reset Operation...
Страница 69: ...12 41 CONTROL SYSTEM SM DLF 1 A 1 GB 12 11 7 Segment Legend 7 7 segments lege end...
Страница 91: ...14 2 SM DLF 1 A 1 GB EXPLODED VIEWS AND SPARE PARTS LISTS 14 2 Indoor Unit DLF 18 DCI...
Страница 95: ...14 6 SM DLF 1 A 1 GB EXPLODED VIEWS AND SPARE PARTS LISTS 14 4 Indoor Unit DLF 24 DCI E F G D E D D E D...
Страница 96: ...14 7 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 14 5 Indoor Unit DLF 24 DCI...