MicroMAX Hardware Installation User Guide
Page 74
Commercial in Confidence
UWB-D00068 Rev J
This cable connects between the rear panel of the AC/DC Converter and the -48V Power Input on
the Front Panel of the BSDU.
Note:
Ensure that:
The
POSITIVE
output of the AC/DC Converter is connected to the
POSITIVE
(Red) input (lower) on the BSDU.
The
NEGATIVE
output of the AC/DC Converter is connected to the
NEGATIVE
(Black) input (upper) on the BSDU.
16.4 Cable Connection
Caution:
Confirm that all inputs to the AC/DC converter are either
disconnected or powered off prior to installing the cable, otherwise damage
may occur to either or both devices.
To connect the BSDU to AC/DC Converter Cable
1. Connect the end of cable 63000110 labeled
BSDU
to the
PS MNG
port on the back panel of
the BSDU, as shown below.
Figure 63 - BSDU to PS MNG port
2. Connect the end of cable 63000110 marked ‘PSU’ to the ‘J1’ port on the back panel of the
AC/DC Convertor, as shown below.
Figure 64 - PSU to J1 port
3. Connect the Black crimped wire from the 25-pin cable connected to Port J1 on the back
panel of the AC/DC Convertor to the –VDC (Negative) output of the AC/DC Convertor on the
back panel, as shown below.