10 Mounting the BSDU
The BSDU can be mounted in either of the two (2) following ways:
¾
Horizontally on a desktop
¾
Horizontally in a rack (ETSI or 19“)
10.1 Desktop mounting
The BSDU can simply be placed horizontally on a table. You can attach to the BSDU's bottom
panel, four rubber feet (pads) (supplied) on each corner to provide cushioning and insulation from
static electricity.
Warning:
To prevent a fire hazard caused by overheating, do not place the
BSDU on a surface where airflow is restricted.
10.2 Rack mounting
The BSDU is designed for mounting in a standard 19-inch (48.3 cm) ETSI equipment rack or telco
rack with 1-rack unit (1-U) of vertical rack space. Mounting bracket flanges are provided for
mounting the BSDU into the cabinet, in its kit. Therefore, all that is required for mounting the
BSDU is to attach the BSDU front-rail mounting brackets to the rack's mounting rails using the
supplied four M5-mounting screws and plastic cup washers.
To rack-mount the BSDU:
1. Determine the rack rail holes (left and right side) that will be used for attaching the chassis.
2. Insert four nuts into the rack's rail holes you designated in Step 1. These nuts are housed in
Tinnerman clips, which allow you to fasten them into the rail holes. To insert the Tinnerman
clips, hold the clips, squeeze them, and then insert them into the rail hole.
3. Carefully insert the BSDU into the rack, aligning the BSDU's mounting bracket holes with the
rack rail holes.
4. Insert the M5-mounting screws, with plastic washers, into the BSDU mounting bracket holes,
on each side, as shown in figure below. In this way, the chassis is supported until you tighten
the chassis screws.
5. Tighten the M5-mounting screws to fasten the chassis to the cabinet.