Setup and Test
145
For networks where co or adjacent frequencies are reused to provide cellular type
network coverage with limited available spectrum (ie. A relatively high level of co and
adjacent channel interference), the following CT Rx levels apply:
Rx Level (dBm / RW)
Modulation
Code
Rate
Below 3GHz
Above
3GHz
Session
ids for
LAT TE
command
in Mode 3
QPSK
1/2
-103 dBm
-100dBm
58 or 59
QPSK
3/4
-101 dBm
-98dBm
56 or 57
16QAM
1/2
-94 dBm
-92dBm
54 or 55
16QAM
3/4
-90 dBm (see note 1)
-88dBm
52 or 53
64QAM
3/4
Not supported on the uplink
Table 1a
1. To set the receive sensitivity, first set up a test network for the band under test as
shown below. The figure below shows a typical test setup with test equipment
connected directly to the outputs of the DIP/LNA and DIP/LNA2 as would be the case
for systems without a RF coupler.
Test Set-up
2. Zero power meter. Calibrate and apply measurement offset for operational frequency
if applicable.
3. On the AS4020 go to Top Menu >Setup Menu >RF Menu>RX Sensitivity. Set RX to
2500
4. Put AS4020 Shelf into test mode
Off
and then into test mode 3. (from AS4020 menu
select Setup Menu/RF Menu/RF Commissioning)
5. Configure the Test SIU using AS7020STMON according to modem shelf properties to
the correct frequency, PN code and ID number prior to entering test mode. The
commissioning procedure described in this document is not restricted to any
particular RF channel or PN code. However the user should make sure that both the
CT and ST are programmed with identical RF channel and PN code. If the frequency
can be entered using STMON then the FP command in the step 12 is not necessary)
6. Measure and calibrate the loss of all components shown in the diagram above. To
measure the losses of components use the TX output as a reference source.
Measure the TX output and place figure in table below.. Connect each component in
Содержание AS4000
Страница 2: ......
Страница 6: ...Printed Documentation 2 ...
Страница 14: ...Printed Documentation 10 ...
Страница 16: ...Printed Documentation 12 ...
Страница 27: ...Installation 23 Typical 75ohm DDF Layout ...
Страница 28: ...Printed Documentation 24 ...
Страница 38: ...Printed Documentation 34 AC Rack Labeling The racks should be labelled as shown below Access Concentrator Rack ...
Страница 39: ...Installation 35 Interface Connections This page contains miscellaneous interface and connector details ...
Страница 41: ...Installation 37 ...
Страница 42: ...Printed Documentation 38 BNC Terminations to Coax ...
Страница 43: ...Installation 39 Type 43 Terminations to Coax ...
Страница 44: ...Printed Documentation 40 ...
Страница 52: ...Printed Documentation 48 ...
Страница 68: ...Printed Documentation 64 ...
Страница 69: ...Installation 65 Interface Connections This page contains miscellaneous interface and connector details ...
Страница 71: ...Installation 67 ...
Страница 72: ...Printed Documentation 68 CT Rack Labelling Central Terminal Rack ...
Страница 73: ...Installation 69 BNC Terminations to Coax ...
Страница 74: ...Printed Documentation 70 Type 43 Terminations to Coax ...
Страница 75: ...Installation 71 ...
Страница 78: ...Printed Documentation 74 Card Insertion DA Rack Card Insertion Expansion Rack ...
Страница 110: ...Printed Documentation 106 ...
Страница 112: ...Printed Documentation 108 Combiner Shelf PSU ...
Страница 133: ...Setup and Test 129 ...
Страница 151: ...Setup and Test 147 11 From the AS4020 front panel exit commissioning mode by selecting RF Commissioning Off ...
Страница 163: ...Setup and Test 159 ...
Страница 166: ......
Страница 170: ...Printed Documentation 166 ...
Страница 176: ...Printed Documentation 172 ...
Страница 192: ......