Setup and Test
139
attenuators
c
Power meter reading with coupler
d
Difference between readings
e
Coupler loss
if [c] is greater than [b] then subtract
[d] from [a]
if [c] is less than [b] then add [d] to [a]
Table 2
11. Populate the table below with values obtained from calibrated components and
planned levels to calculate/determine overall path loss and required ST output power
and hence required power meter reading.
RF Channel
No:
Cable Loss
(1)
Coupler loss loss.
(2)
RF Section
Loss Antenna-
CT( DACU RF Module).
(3)
Sub Total
(4)
=
1+2+3
Required CT RX Level
(5)
See table 1 above.
DACU RF Power
(6)
=4+5
RF Section
Loss Antenna - Power Meter
(7)
Power Meter
(8)
= 6-7
Table 3
12. Make the test ST transmit by sending the following LAT commands from a terminal
emulator connected to the DACU
TE<space> 0<space> 4<space> 59 (this code sets the uplink modulation rate for the
ST for other required modulations replace the 59 with the session ids shown in table
1 above and should be set to the maximum modulation rate required)
FP <space>channel number (in decimal)
W<space> 0400003C
13. The terminal emulator should receive 0000000B for the uplink if the ST has acquired
a link.
14. On the AS4020 top panel go to Top Menu >Setup Menu >RF Menu>RX Sensitivity
15. Set RX gain by increasing/decreasing the value of RX sensitivity to achieve required
ST o/p level calculated as ( 8) in the table above for the required RX Level measured
on the power meter.
16. Record the value set in the test results
Link check
1. Enable the equalizer by typing the following LAT commands
ADE 1 10 (this enables the downlink channel equalizer and it should converge within
10 seconds)
ADS (this command displays the equalizer stats).
When the equalizer is adapting the stat reports Enabled = 1 Converged = 0
When the equalizer is adapting the stat reports Enabled = 0 Converged = 1 (the 0 for
Содержание AS4000
Страница 2: ......
Страница 6: ...Printed Documentation 2 ...
Страница 14: ...Printed Documentation 10 ...
Страница 16: ...Printed Documentation 12 ...
Страница 27: ...Installation 23 Typical 75ohm DDF Layout ...
Страница 28: ...Printed Documentation 24 ...
Страница 38: ...Printed Documentation 34 AC Rack Labeling The racks should be labelled as shown below Access Concentrator Rack ...
Страница 39: ...Installation 35 Interface Connections This page contains miscellaneous interface and connector details ...
Страница 41: ...Installation 37 ...
Страница 42: ...Printed Documentation 38 BNC Terminations to Coax ...
Страница 43: ...Installation 39 Type 43 Terminations to Coax ...
Страница 44: ...Printed Documentation 40 ...
Страница 52: ...Printed Documentation 48 ...
Страница 68: ...Printed Documentation 64 ...
Страница 69: ...Installation 65 Interface Connections This page contains miscellaneous interface and connector details ...
Страница 71: ...Installation 67 ...
Страница 72: ...Printed Documentation 68 CT Rack Labelling Central Terminal Rack ...
Страница 73: ...Installation 69 BNC Terminations to Coax ...
Страница 74: ...Printed Documentation 70 Type 43 Terminations to Coax ...
Страница 75: ...Installation 71 ...
Страница 78: ...Printed Documentation 74 Card Insertion DA Rack Card Insertion Expansion Rack ...
Страница 110: ...Printed Documentation 106 ...
Страница 112: ...Printed Documentation 108 Combiner Shelf PSU ...
Страница 133: ...Setup and Test 129 ...
Страница 151: ...Setup and Test 147 11 From the AS4020 front panel exit commissioning mode by selecting RF Commissioning Off ...
Страница 163: ...Setup and Test 159 ...
Страница 166: ......
Страница 170: ...Printed Documentation 166 ...
Страница 176: ...Printed Documentation 172 ...
Страница 192: ......