~11~
~10~
Fill solution tank (1). Always use
solution funnel (143) with filter.
(Fig. 8)
Only fill the required solution amount
for application.
NEVER fill the fuel into the
solution tank (1).
Place tank cap (2) in proper position
then close it tightly.
Make sure that solution tap (120) is
closed. Lever points upwards.
(Fig. 9)
Tighten the air intake valve (30) and
swirl vane (26).
(Fig. 10)
143
Fig.8
120
2
Fig.9
7)
8)
30
26
Fig.10
9)
!
1
7. Select Fog Solution Output and Fog Tube:
Solution throughput of the available dosage nozzle (measured with water).
Solution nozzle size Ø
throughput L/H, approx.
0.6
5
0.7
8
0.8
12
1.0
18
1.2
23
1.4
36
1.6
42
The outputs vary according to different chemicals and physical propertises
of the formulations. We advice that you do your own metering of the output
under prevailing conditions.
For
water based
solutions choose nozzles up to Ø1.0 mm.
For better performance, we recommend special fog tube (109) and fog solution
socket (114/1) for water based product.
For
oil based
solutions we recommend nozzle sizes Ø 0.8 and above.
Then use the standard oil based fog tube (108) ONLY.
Smaller nozzles reduce the droplet spectrum. Larger nozzles may cause
an unsatisfactory droplet spectrum.
Never operate the appliance with the water based fog tube when oil
based fogging mixtures with carriers of inflammable substances are
applied.
!