1) Prepare the appliance in the normal way
and start, then let it warm up for at least
1 minute. Engage the operating lever
(EC13) for appr. 10 sec. and stop the
appliance. The operating lever must be
released automatically.
(Fig. 29)
AR9E / AR35E is equipped with an emgency cut-off device (called “EC”). Every
appliance was given the final inspection at the factory of manufacturer, so adjustment
is not needed when starting the appliance. However, it is necessary after a repair or
blocking.
Check of function. Please proceed as follows:
15. Emergency Cut-off Device
EC 13
Fig. 29
Engage
Release
2) Start the appliance and engage the
operating lever.
Open solution tap (120), now fogging
thrust should be seen.
(Fig. 30)
3) Stop the appliance, operating lever will be
released automatically, the fogging should
stop now.
(Fig. 31)
4) Check no solution leak from screw
housing (EC27), valve housing (EC33)
and solution nozzle (114).
(Fig. 32)
EC13
OPEN
Fig.31
Release
Oil
Fig.32
EC27
EC33
114
!
After every check of function, immediately close solution tap and release
pressure from solution tank by loosen the tank cap.
Always check the function of the “EC” when starting. The appliance may only be
operated when the “EC” function correctly.
EC 25 EC 24
Fig.28
EC 23
The fine adjustment of the Bowden Cable (EC23)
can only be effective when the appliance is warm
up:
- ajust the tension of the Bowden Cable (EC23)
by tuning the screw-type nipple (EC25)
inwards / outwards.
- after correct adjustment, tighten the nut (EC24).
(Fig. 28)
EC 13
Engage
120
Fig.30