~15~
~14~
10. The Appliance Stops Unexpectedly
Take the following urgent measures when the appliance stops unexpectedly
due to a lack of fuel or mechanical failure:
- Close the solution tap (120) immediately.
Close the solution tap to avoid the fogging
mixture being conveyed by the over -
pressure in the solution tank and reaching
into the hot resonator without being
fogged.
There combustible fogging mixtures can
ignite, thereby creating the risk of fire at
the carburetor and / or fogging outlet.
(Fig. 14)
- Hold the appliance with the fog mixing
tube pointing downwards.
The appliance has to be held with the
fog mixing tube pointing downwards
to allow the chemical solution residue
to run out. Small quantities of
combustible solution can ignite and
have to be extinguished immediately.
(Fig. 15)
It is not allowed to leave the appliance unattended while operating in any case.
Fig.14
120
Fig.15
Oil
!
11. Stopping the Appliance:
1) Close solution tap (120) by 1/4 turn to clear
or ventilate the solution pipe (116).
(Fig. 16)
2) Wait until fog is no longer visible. Now close
solution tap (120) completely(lever upwards).
(Fig. 17)
3) Press stop button (52) until no explosions are
audible.
(Fig. 18)
4) Release pressure from solution tank by
unscrewing the solution tank cap (2) by 1 to 2
turns then retighten the cap.
(Fig. 19)
After stop the appliance always release
pressure from solution tank because the
solution tank is still under pressure and
solution can get out when the solution tap
open by mistake.
Fig.16
120
116
120
Fig.17
52
Fig.18
Fig.19
2
!