12
-All rooms require an openable window, or
equivalent and some rooms will require a
permanent vent a well.
-For room volumes up to 5 m
3
an air vent of 100cm
2
is required.
-For room volumes between 5 m
3
and 10 m
3
an air
vent of 50 cm
2
is required.
-If the room is greater than 5 m
3
and has a door
that opens directly to the outside, then no air vent
is required.
If there are other fuel burning appliances in the
same room BS 5440: Part 2:1989 should be
consulted to determine the air vent requirements.
Gas connection
Make sure that the appliance is adjusted for
the gas type available (see the label under the
appliance). Follow the instructions indicated in the
chapter “gas transformations and adjustments” for
the possible adaptation to different gases.
The appliance must be connected to the gas
s y s t e m b y
means of stiff
metal pipes or
flexible steel
p i p e s h a v i n g
continuous walls,
in compliance
w i t h t h e
regulations in
force.
Some models are equipped with both cylindrical A
and conical B connectors for gas supply (fig.7).
Please select the type which is correct for the
supply concerned.
The connection must not stress the gas ramp.
Once the installation is over, check the
connection seal with a soapy solution.
Electric connection
The connection to the electric grid must be carried
out by qualified personnel and in conformity with
the regulations in force.
The voltage of the electric system must correspond
to the value indicated in the label under the
appliance. Make sure that the electric system is
provided with an effective ground connction in
compliance with the regulations and provisions of
the law.
Grounding is compulsory.
If the appliance is not equipped with a plug, apply
a standardized plug to the power supply cable.
This device must be at a suitable opening distance
from the contacts in order to allow the entire
disconnection in case of overvoltage category
III
,
in accordance with installation rules.
GAS TRANSFORMATIONS AND ADJUSTMENTS
Replacing the nozzles
If the equipment is adjusted for a type of gas that is
different from the one available, it is necessary to
replace the burner nozzles.
Fig.8
The choice of the nozzles to replace must be
made according to the table of the “technical
characteristics” as enclosed.
Act as follows:
-Remove the racks and burners.
-By means of a straight spanner L, unscrew
the nozzle U (fig.8) and substitute it with the
corresponding one.
-Tighten the nozzle strongly.
Adjusting the burners
The lowest flame point must always be properly
adjusted and the flame must remain on even if
there is an abrupt shift from the maximum to the
minimum position.
If this is not so, it is necessary to adjust the lowest
flame point as follows:
-start the burner up;
-turn the tap up to the minimum position (small
flame);
-remove the knob from the tap rod;
-introduce a flat-tip screwdriver C in the hole
of control panel of the tap (fig. 9) and turn the
by-pass screw V (fig.9/A) up to a proper
adjustment of the lowest flame point.
Fig.9
Fig.9/A
As regards G30 gas burners, the by-pass screw
must be tightened completely.
INSTRUCTIONS FOR THE INSTALLER
Fig.7
Содержание AT635HIX
Страница 1: ......
Страница 2: ......
Страница 30: ......
Страница 31: ......
Страница 32: ...29 COD 208776 07 06 2016...