8.2.1 AirLeash Magnetometer (Mag) Calibration
Calibrate magnetometer (Mag) on AirLeash
only
if you see the error message:
“Mag failed! Calibrate Mag!” displayed on AirLeash during the AirLeash Preflight
Check. The magnetometer is very sensitive to magnetic interference and its
calibration requires an interference-free environment. Stay away from metal
structures and concrete floors or large buildings. Do not wear gloves or rings with
magnets or other
ferromagnetic metal
s while performing the calibration steps.
AirLeash Mag calibration process:
1. Turn on AirLeash by long pressing (3 sec.) the Power/OK
button.
2. Short press the Menu
button to enter Menu.
3. Navigate through the Menu with arrow left
or right
buttons until you see
the Settings icon on the AirLeash display.
4. Short press the Power/OK
button to enter Settings.
5. Navigate through the Settings with arrow left
or right
buttons until you
see the Calibration
icon on the display.
6. Short press on the Power/OK
button to enter the Calibration menu.
7. Navigate through the Calibration menu with arrow left
or right
buttons
until you see the AirLeash calibration
icon.
8. Short press the Power/OK
button to enter AirLeash Calibration menu.
9. Navigate through the AirLeash Calibration menu with arrow left
or right
buttons until you see the Magnetometer
icon on the AirLeash display.
10. Short press the Power/OK
button to select the magnetometer calibration.
11. You can scroll down with arrow down
button to read the calibration tips or
short press the Power/OK
button to start the calibration. It is strongly advised
to watch the calibration videos at help.airdog.com before you calibrate any
sensors!
12. Calibration will start after 5 sec., a message stating
“Hold THIS side up”
with
an Arrow pointing to the side that you must hold up will appear on AirLeash
display:
HOLD THIS SIDE UP