background image

 

CAUTION: Do not spill water on fan motor. Electrical components must be 
kept dry. 

ABOUT HUMIDITY 

Where you set your desired humidity levels depends on your personal comfort 
level, the outside temperature and the inside temperature.  

NOTE

: Recent CDC tests show that the chances of flu transmission are greatly 

reduced at levels of 43% humidity. 
You may wish to purchase a hygrometer* to measure the humidity level in your 
home. The following is a chart of recommended humidity settings. 

NOTE: 

 We 

recommend using AIRCARE

®

 or Essick Air

®

 Bacteriostat Treatment when you 

refill the water reservoir to eliminate bacterial growth.  Add bacteriostat according 
to the instructions on the bottle. 
Under no circumstances should  you use Water Treatment products intended for 
Rotobelt or Ultrasonic humidifiers. 

 

When Outdoor 

Temperature is: 

    °F 

       ° 

C  

 

Recommended 

Indoor Relative 

Humidity (RH) is 

-20 

-10° 

  2° 
10° 
20° 
30°  

-30° 
-24° 
-18° 
-12° 

 -6° 
 -1° 

15 - 20% 
20 - 25% 
25 - 30% 
30 - 35% 
35 - 40% 
40 - 45% 

*Model 1990 digital hygrometer is available for purchase by calling 1-800-547-3888. 

NOTE:

 External hygrometer readings and humidistat  readings may differ. 

Humidity levels can vary significantly even in one room. 

OPERATION 

Plug cord into wall receptacle. Your humidifier is now ready for use.  The humidifier should 

be placed at least FOUR inches away from any walls and away from heat registers. 

Unrestricted airflow into the unit will result in the best efficiency and performance. 

NOTE:

 This unit has an automatic  humidistat located on the cord that senses the 

humidity level around the immediate area of the humidifier. It turns the humidifier on when 
the relative humidity in your home is below the humidistat setting and will turn the 
humidifier off when the relative humidity reaches the humidistat setting. 

 

TO TURN ON/OFF 

For initial operation

, plug the unit 

in (the display will show - -). Press 
the speed button and hold for 5 
seconds to turn the unit on or off. 

FAN SPEED

 

The 3D6100 has a four  speed 

digital control panel. 

1)  Press the SPEED button to 

adjust the fan speeds.

 

2)  The speeds: High (F4) - Low 

(F1) display on the digital panel.

 

 

 

PRESS AND HOLD

TO  TURN UNIT ON

PUSH TO ADJUST

FAN SPEED

PRESS TO

INCREASE

HUMIDITY

DIGITAL DISPLAY

IMPORTANT: Water damage 
may result if condensation 
starts to form on windows or 
walls. Humidity SET point 
should be lowered until 
condensation no longer forms. 
We recommend room humidity 
levels do not exceed 50%. 

Содержание 3D6100

Страница 1: ...00 USE AND CARE GUIDE Auto Humidistat Four Speed Fan Dual water bottles TO ORDER PARTS AND ACCESSORIES CALL 1 800 547 3888 COMFORT IS IN THE AIR 1B72878 112014 PRINTED IN CHINA HUMIDITY HUMIDITY RANGE...

Страница 2: ...an assembly section from the humidifier or whenever it is not in service 4 Keep the humidifier clean To reduce the risk of injury fire or damage to humidifier use only cleaners specifically recommende...

Страница 3: ...tion of water in the air Once the wick becomes saturated air is drawn in passes through the wick and moisture is absorbed into the air All evaporation occurs in the humidifier so any residue remains i...

Страница 4: ...it will continue running even when out of water 1 Remove water bottles and unscrew caps on bottom Fill bottle with unsoftened water Replace caps and tighten securely Use both hands to carry each bottl...

Страница 5: ...er Humidity levels can vary significantly even in one room OPERATION Plug cord into wall receptacle Your humidifier is now ready for use The humidifier should be placed at least FOUR inches away from...

Страница 6: ...tings the controls can be locked ACTIVATION PROCEDURE After the humidifier functions have been set up hold the Speed and Humidity buttons down for 5 seconds The display will show CL for 2 seconds Rele...

Страница 7: ...in the and DISINFECTING UNIT sections below 4 Lift the wicks from the base allowing excess water to drain 5 Rinse wicks under freshwater only Do not use soap detergent or any other cleaners on the wic...

Страница 8: ...ding failure to perform reasonable maintenance normal wear and tear nor where the connected voltage is more than 5 above the nameplate voltage Alterations include the substitution of name brand compon...

Страница 9: ...t automatique Ventilateur quatre vitesses Deux r cipients amovible POUR COMMANDER DES PI CES ET DES ACCESSOIRES APPELEZ LE 1 800 547 3888 LISEZ ET CONSERVEZ CES INSTRUCTIONS Anglais 1 Espa ol 17 LE CO...

Страница 10: ...ur r duire le risque de blessure d incendie ou de dommages l humidificateur utilisez uniquement des produits de nettoyage sp cialement recommand s pour les humidificateurs N utilisez jamais de mat ria...

Страница 11: ...tres m che d autres marques nuit aux performances de l appareil et peut annuler votre garantie FONCTIONNEMENT DE L HUMIDIFICATEUR Votre nouvel humidificateur a t con u pour satisfaire les exigences d...

Страница 12: ...llez avoir le num ro de s rie de l humidificateur lors de votre appel REMPLISSAGE D EAU MISE EN GARDE Avant le remplissage assurez vous que l appareil est teint et d branch NOTE Unit continuera de tou...

Страница 13: ...itation est de F C 20 10 2 10 20 30 30 24 18 12 6 1 15 20 20 25 25 30 30 35 35 40 40 45 Mod le1990hygrom trenum riqueestdisponible l achatpart l phoneau 1 800 547 3888 REMARQUE Lectures de externes et...

Страница 14: ...ra t lorsque l humidificateur est rebranch VERROUILLAGE DES COMMANDES Pour viter la manipulation ind sirable des param tres de l humidificateur les commandes peuvent tre verrouill es PROC DURE D ACTIV...

Страница 15: ...tres m che en laissant l exc s d eau s couler 5 Rincez le filtre m che sous de l eau fra che uniquement N utilisez pas de savon de d tergent ni d autres nettoyeurs sur les filtres m che Laissez le s g...

Страница 16: ...t la substitution d l ments de marque y compris mais sans s y limiter les m ches d humidificateur et le traitement des bact ries Nous n assumons pas la responsabilit de tout dommage r sultant de l uti...

Страница 17: ...stato autom tico 4 velocidades del ventilador Botellas de agua dobles PARA ADQUIRIR PIEZAS Y ACCESORIOS LLAME AL 1 800 547 3888 LEA Y GUARDE ESTAS INSTRUCCIONES HUMIDITY HUMIDITY RANGE 25 65 RANGE 25...

Страница 18: ...entilador del humidificador o cuando no est funcionando 4 Mantenga el humidificador limpio Para reducir el riesgo de lesiones incendio o da os al humidificador utilice solamente limpiadores recomendad...

Страница 19: ...nelaire Todala evaporaci nseproduceenel humidificadorparaquecualquier residuo permanezcaenelfiltro Este proceso natural de evaporaci n elimina pr cticamente todo el polvo blanco Descripci n 3D6 100 Re...

Страница 20: ...DA y desenchufada Nota La unidad continuar funcionando incluso cuando est fuera del agua 1 Retire las botellas de agua y desenrosque la tapa Llene las botellas con agua sin ablandar Vuelva a colocar l...

Страница 21: ...luso en una habitaci n OPERACI N Conecte el enchufe en un tomacorriente de pared Su humidificador ya est listo para ser utilizado El humidificador se debe colocar a DIEZ cent metros como m nimo de cua...

Страница 22: ...restablecer la m xima eficiencia La funci n CF vuelve a cero luego de conectar la unidad nuevamente FUNCI N DE BLOQUEO DEL CONTROL 2 Para evitar que los ajustes del humidificador se vean alterados in...

Страница 23: ...INFECCI N DE LA UNIDAD 4 Lleve la base a la pileta Levante las mechas de la base dejando que salga el exceso de agua 5 Enjuague la mecha solamente con agua limpia No use jab n detergente o cualquier o...

Страница 24: ...e normal ni en situaciones donde el voltaje conectado sea un 5 mayor al indicado por la placa indicadora Las alteraciones que puede sufrir el producto incluyen la sustituci n de componentes de marca i...

Отзывы: