background image

 

INTRODUCTION 

Your new humidifier adds invisible moisture to your home by moving dry inlet air 
through a saturated wick.  As air moves through the wick, the water evaporates into 
the air, leaving behind any white dust, minerals, or dissolved and suspended solids.  
Because the water is evaporated, there is just clean and invisible moist air. 
As the evaporative wick traps accumulated minerals from the water, its ability to 
absorb and evaporate water decreases.  We recommend changing the wick at the 
beginning of every season.  In hard water areas, more frequent replacement may 
be necessary to maintain your humidifier’s efficiency. 
Use only AIRCARE

®

 or Essick Air

®

  brand replacement wicks and chemicals.  To 

order parts, wicks and chemicals call 1-800-547-3888.  This humidifier uses two 
wicks # 1040. Only the AIRCARE

®

 or Essick Air

®

 evaporative wick guarantees the 

certified output of your humidifier. Use of other brands of wicks voids the 
certification of output and may void your warranty.

 

HOW YOUR HUMIDIFIER WORKS 

Your new evaporative humidifier is designed 
to satisfy home humidity requirements 
through the principle of evaporation of water 
in the air. 
Once the wick becomes saturated, air is 
drawn in, passes through the wick and 
moisture is absorbed into the air.  All 
evaporation occurs in the humidifier so any 
residue remains in the wick.

 

This natural process of evaporation creates no white dust like some other humidifiers.

Description

3D6 100

Water Capacity  

3 Gallons 

Sq. ft. coverage 

1800 (Tight Constr.) 
1200 ( Avg. Constr.)  

Fan Speeds 

Replacement Wicks (2 required) 

1040 

Auto Humidistat 

Yes 

Controls Digital 
ETL Listed 

Yes 

Volts 120 
Hertz 60 
Watts 40 

  

    

* Based on an area with average insulation and an 8’ ceiling height. 

NOTES ON LOCATION

In order to get the most effective use from your humidifier, it is important to 

position the unit where the most humidity is needed or where the moist air will be 

circulated throughout the house such as near a cold air return. If the unit is 

positioned close to a window, condensation may form on the window pane. If this 

occurs the unit should be repositioned in another location. 
Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT 
place on soft carpet.  
Due to release of cool, moist air from the humidifier, it is best to direct air away 
from thermostat and hot air registers. Position humidifier next to an inside wall on 
a level place at least 4 inches away from the wall or curtains. 

Содержание 3D6100

Страница 1: ...00 USE AND CARE GUIDE Auto Humidistat Four Speed Fan Dual water bottles TO ORDER PARTS AND ACCESSORIES CALL 1 800 547 3888 COMFORT IS IN THE AIR 1B72878 112014 PRINTED IN CHINA HUMIDITY HUMIDITY RANGE...

Страница 2: ...an assembly section from the humidifier or whenever it is not in service 4 Keep the humidifier clean To reduce the risk of injury fire or damage to humidifier use only cleaners specifically recommende...

Страница 3: ...tion of water in the air Once the wick becomes saturated air is drawn in passes through the wick and moisture is absorbed into the air All evaporation occurs in the humidifier so any residue remains i...

Страница 4: ...it will continue running even when out of water 1 Remove water bottles and unscrew caps on bottom Fill bottle with unsoftened water Replace caps and tighten securely Use both hands to carry each bottl...

Страница 5: ...er Humidity levels can vary significantly even in one room OPERATION Plug cord into wall receptacle Your humidifier is now ready for use The humidifier should be placed at least FOUR inches away from...

Страница 6: ...tings the controls can be locked ACTIVATION PROCEDURE After the humidifier functions have been set up hold the Speed and Humidity buttons down for 5 seconds The display will show CL for 2 seconds Rele...

Страница 7: ...in the and DISINFECTING UNIT sections below 4 Lift the wicks from the base allowing excess water to drain 5 Rinse wicks under freshwater only Do not use soap detergent or any other cleaners on the wic...

Страница 8: ...ding failure to perform reasonable maintenance normal wear and tear nor where the connected voltage is more than 5 above the nameplate voltage Alterations include the substitution of name brand compon...

Страница 9: ...t automatique Ventilateur quatre vitesses Deux r cipients amovible POUR COMMANDER DES PI CES ET DES ACCESSOIRES APPELEZ LE 1 800 547 3888 LISEZ ET CONSERVEZ CES INSTRUCTIONS Anglais 1 Espa ol 17 LE CO...

Страница 10: ...ur r duire le risque de blessure d incendie ou de dommages l humidificateur utilisez uniquement des produits de nettoyage sp cialement recommand s pour les humidificateurs N utilisez jamais de mat ria...

Страница 11: ...tres m che d autres marques nuit aux performances de l appareil et peut annuler votre garantie FONCTIONNEMENT DE L HUMIDIFICATEUR Votre nouvel humidificateur a t con u pour satisfaire les exigences d...

Страница 12: ...llez avoir le num ro de s rie de l humidificateur lors de votre appel REMPLISSAGE D EAU MISE EN GARDE Avant le remplissage assurez vous que l appareil est teint et d branch NOTE Unit continuera de tou...

Страница 13: ...itation est de F C 20 10 2 10 20 30 30 24 18 12 6 1 15 20 20 25 25 30 30 35 35 40 40 45 Mod le1990hygrom trenum riqueestdisponible l achatpart l phoneau 1 800 547 3888 REMARQUE Lectures de externes et...

Страница 14: ...ra t lorsque l humidificateur est rebranch VERROUILLAGE DES COMMANDES Pour viter la manipulation ind sirable des param tres de l humidificateur les commandes peuvent tre verrouill es PROC DURE D ACTIV...

Страница 15: ...tres m che en laissant l exc s d eau s couler 5 Rincez le filtre m che sous de l eau fra che uniquement N utilisez pas de savon de d tergent ni d autres nettoyeurs sur les filtres m che Laissez le s g...

Страница 16: ...t la substitution d l ments de marque y compris mais sans s y limiter les m ches d humidificateur et le traitement des bact ries Nous n assumons pas la responsabilit de tout dommage r sultant de l uti...

Страница 17: ...stato autom tico 4 velocidades del ventilador Botellas de agua dobles PARA ADQUIRIR PIEZAS Y ACCESORIOS LLAME AL 1 800 547 3888 LEA Y GUARDE ESTAS INSTRUCCIONES HUMIDITY HUMIDITY RANGE 25 65 RANGE 25...

Страница 18: ...entilador del humidificador o cuando no est funcionando 4 Mantenga el humidificador limpio Para reducir el riesgo de lesiones incendio o da os al humidificador utilice solamente limpiadores recomendad...

Страница 19: ...nelaire Todala evaporaci nseproduceenel humidificadorparaquecualquier residuo permanezcaenelfiltro Este proceso natural de evaporaci n elimina pr cticamente todo el polvo blanco Descripci n 3D6 100 Re...

Страница 20: ...DA y desenchufada Nota La unidad continuar funcionando incluso cuando est fuera del agua 1 Retire las botellas de agua y desenrosque la tapa Llene las botellas con agua sin ablandar Vuelva a colocar l...

Страница 21: ...luso en una habitaci n OPERACI N Conecte el enchufe en un tomacorriente de pared Su humidificador ya est listo para ser utilizado El humidificador se debe colocar a DIEZ cent metros como m nimo de cua...

Страница 22: ...restablecer la m xima eficiencia La funci n CF vuelve a cero luego de conectar la unidad nuevamente FUNCI N DE BLOQUEO DEL CONTROL 2 Para evitar que los ajustes del humidificador se vean alterados in...

Страница 23: ...INFECCI N DE LA UNIDAD 4 Lleve la base a la pileta Levante las mechas de la base dejando que salga el exceso de agua 5 Enjuague la mecha solamente con agua limpia No use jab n detergente o cualquier o...

Страница 24: ...e normal ni en situaciones donde el voltaje conectado sea un 5 mayor al indicado por la placa indicadora Las alteraciones que puede sufrir el producto incluyen la sustituci n de componentes de marca i...

Отзывы: