AIMS Power
www.aimscorp.net
- 16 -
Allow at least 6 inches of clearance around the inverter for air flow. Make sure that the air can circulate
freely around the unit.
Fan noise level <60db at a distance of 3 feet.
2.5.11 Other Features
Battery voltage recovery start
After low battery voltage shut off (10V for 12V model
)
, the inverter is able to restore operation after the
battery voltage recovers to 13V (with power switch still in the “On” position).
This function helps users
and saves time and extra labor to reactivate the inverter when the low battery voltage returns to an
acceptable range in renewable energy systems. The built in battery charger will automatically reactivate
as soon as city/generator AC has been stable for 15 seconds.
Never leave the loads unattended, some loads (like a
h
eater) may cause accidents in such cases.
It is better to shut everything off after low voltage trip than to leave your load on, due to the risk of fire.
Conformal Coating
AIMS Power entire line of Global LF inverters have been processed with a conformal coating on the
PCB, making it water, rust, and dust resistant as well as corrosion resistant.
While these units are designed to withstand corrosion from the salty air, they are not splash proof.
2.5.10
FA
N
Operation
Condition
Enter Condition
Leave condition
Speed
HEAT SINK
T ≤ 140℉
T > 149℉
OFF
TEMPERATURE
149℉≤ T < 185℉
T ≤ 140℉ or T ≥ 185℉
50%
T > 185℉
T ≤ 176℉
100%
CHARGER
CURRENT
I ≤ 15%
I ≥ 20%
OFF
20%< I ≤ 50%Max
I≤ 15% or I > 50%Max
50%
I > 50%Max
I ≤ 40%Max
100%
LOAD Percentage
(INV MODE)
Load < 30%
Load ≥ 30%
OFF
30% ≤ Load < 50%
Load ≤ 20% or Load ≥ 50%
50%
Load ≥ 50%
Load ≤ 40%
100%
The Operation of the DC fan at the DC terminal side is controlled by the following logic: