21
LS1+TIMER
・
Fastening operation will start at the time of LS1 input, and the line control timer will also start.
When the preset fastening number is attained, COUNT OK will result, and then LS1 input will
be accepted only after COUNT OK terminal output (output duration time can be set by using
COUNT OK output timer).
・
If the line control timer has become time-out before completing the preset fastening number,
COUNT NOK will result. In this case, fastening operation will finish when COUNT OK
judgment is given through NOK handling.
・
Note that COUNT OK terminal output holding (set value: 0) can not be selected when this
function is in use.
TIMER
・
In this method, Limit Switch will not be provided, and the line control timer gets started by
utilizing the initial fastening judgment or QL wrench input.
・
COUNT OK judgment will be given when the preset fastening number is attained, and the next
coming work fastening operation will become ready when COUNT OK output (output duration
time can be set by using COUNT OK output timer) is turned OFF.
・
If the line control timer has become time-out before completing the preset fastening number,
COUNT NOK will result. In this case, fastening operation will finish when COUNT OK
judgment is given through NOK handling.
・
Note that COUNT OK terminal output holding (set value: 0) can not be selected when this
function is in use.
Work
Work flow
NOK handling range
Line control timer
Initial fastening judgment
Judgment
Operating range
Work
Work flow
NOK handling range
LS1
Line control timer
Judgment
Operating range
Alarm output timer
Alarm output
Alarm output timer
Alarm output