16
SET UP
Function Setting
TOOL(
Tool Selection
)
Initial Setting
:SHUT-OFF TYPE
Select any among three selectable tools;
SHUT-OFF TYPE/TM TYPE/NON-
SHUT TYPE
・
This selection is common among
WORK
№
1~4
.
SHUT-OFF TYPE(
Shut-off Tool
)
・
Tool will stop operation automatically upon completing bolt fastening operation, and then TM
Signal will be output.
・
When SHUT-OFF TYPE is selected, ON (Valve ON Timer) and OFF (Valve OFF Timer) initial
values will become “0” respectively.
TM TYPE(
TM Type Tool
)
・
TM Signal will be output during fastening operation. Tool will not stop operation
automatically, and fastening time controlling via UTM will become necessary.
・
When Shut-off Tool is selected, Valve ON Timer and Valve OFF Timer initial values will
become “700” and “800” respectively.
NON-SHUT TYPE(
Standard Tool
)
・
As TM Signal will not be output in this case, Tool Blow Start will be sensed using Tool’s hand
pressure. Tool will not stop operation automatically, and fastening time controlling via UTM
will become necessary.
・
When Standard Tool is selected, ON and OFF initial values will become “700” and “800”
respectively.
SENSOR(
Pressure Sensor Input Type
)
Initial Setting
:NO DISPLAY
Select any among three selections;
NO DISPLAY/DISPLAY/RELAY BOX
・
This selection is common among
WORK
№
1~4
.
NO DISPLAY:
Private external Pressure Sensor Assembly.
Sensor incorporated in Tool
or Controller.
DISPLAY:
Pressure sensor with a digital display
RELAY BOX:
Select when you use Air-electric Relay (without using Pressure Sensor).
* * * SET UP * * *
TOOL: SHUT-OFF TYPE
SENSOR : NO DISPLAY
BLOW START:0.10 MPa
SHUT-OFF: 0.30 MPa
PULSE LV: 0.000 MPa
CUT PULSE No.: 0
UPPER PULSE No.: 0
LOW PULSE No.: 0
■COUNT: 99
L.CONT.:LS1
W.SEL.TIMING: NO
ERROR: REFASTENING
CHECK BZ VOL.: 5
NOK BZ VOL. : 5
KEY BZ VOL. : 5
DISPLAY : Standard