18
UPPER PULSE No. (Upper Pulse Number)
Setting Range
: 0~999
Initial Value
: 0
・
This is the upper limit for pulse number judgment. When the pulse number measured stepped
across the preset number, Pulse HIGH NOK will result.
・
This setting is common among WORK No. 1~4.
・
In the case of 0 setting, pulse number upper limit judgment will not be performed.
Reaction in the case of Pulse HIGH NOK detection:
・
LCD Display
: [Pulse High Error]
・
Buzzer :
ON
・
Output Terminal
: FAS. NOK will be output
Error Condition Resetting
・
In the case that ERROR (refastening at fastening NOK) is set to REFASTENING (fastening
NOK clear at refastening operation start), the next fastening operation will reset error
conditions:
・
RESET key operation or RESET terminal input.
LOW PULSE No. (Lower Pulse Number)
Setting Range
: 0~999
Initial Value
: 0
・
This is the lower limit for pulse number judgment When Tool becomes shut-off condition before
the pulse number measured reached the preset number, Pulse LOW NOK will result.
・
This setting is common among WORK No. 1~4.
・
In the case of 0 setting, pulse number lower limit judgment will not be performed.
Reaction in the case of Pulse LOW NOK detection:
・
LCD Display
: [Pulse Low Error]
・
Buzzer :
ON
・
Output Terminal
: FAS. NOK will be output
Error Condition Resetting
・
In the case that ERROR (refastening at fastening NOK) is set to REFASTENING (fastening
NOK clear at refastening operation start), the next fastening operation will reset error
conditions:
・
RESET key operation or RESET terminal input.
COUNT (Fastening Number)
Initial Value
: 99
Setting Range
: 0~99
・
Set intended fastening number.
・
This is on a WORK No. basis setting.