Tool Connection
・
Make the length of TM Signal air hose between Tool and Pressure Sensor (external pressure
sensor/main body incorporated sensor) or Air-electric Relay as short as possible. A lengthy air
hose may sometimes cause a delay in detecting pneumatic pressure fluctuations or hinder
correct detection. (Shorter than 5m is recommended)
・
In the case of fastening pulse number detection, the length of TM Signal air hose between Tool
and Pressure Sensor must be maintained shorter than 30cm. TM Signal air hose of longer
than 30cm will interfere with air pulsation taking during pulsing.
・
When using TM Tool or Standard Tool, place Solenoid Valve at an adequate point so as the length
of the air hose up to Tool will be maintained as short as possible. When the air hose between
Solenoid Valve and Tool is unnecessary lengthy, Tool stop timing will be delayed due to
residual pressure in the hose even though the valve reacted normally.
(1)
Shut-off Tool (TM)
①
When using UTM-1500(CN) and External Pressure Sensor Assembly
・
Place External Pressure Sensor Assembly as close as possible to Tool.
②
When using UTM-1500 (RA-CN)
・
Same wiring as in the case of without a rack (
①
).
Connector incorporated, with-a-rack
type UTM-1500 (RA-CN)
Pressure Sensor Cable Assembly (5m)
(Part Code:910-820-0)
Pressure Sensor Cable Assembly (10m)
(Part Code:910-821-0)
Hook up Sensor Cable to
Connector at Controller’s back
External Pressure Sensor
Assembly
(Part Code:878-845-1)
TM Signal Air Hose
Connector Incorporated
Type UTM-1500 (CN)