34
SET
After a change, check the laser LCD and wait until SET
appears again on the screen, and move the beam again if
needed.
To save the calibration (beam position), press the
Lock
button on the Remote (or the
ENT
button on the laser
keypad).
If it is not desired to save changes, turn the laser off.
To leave the CALIBRATION mode, move the cursor to
EXIT
and press
ENT
.
(If using the Remote, move up the menu using the Center
Line button and move down the menu using the Standby
(ZZZ) button. Press the Lock button instead of ENT.)
To leave the SET UP mode, move the cursor to
EXIT
and
press
ENT
(or LOCK on the Remote).
Final Calibration Check
Re-check the new calibration using the steps shown in the previous section with Stakes A
and B. If the marks are no more than 1/8 inch apart at 100 feet (at 30 m, no more that 3 mm
apart), the laser is within the accuracy spec and calibrated correctly.