Commands by Subsystem
5
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
575
:TRIGger:SEQuence:EDGE
Command Syntax
:TRIGger:SEQuence:EDGE{1 | 2} <source>, <slope>
<source> ::= {CHANnel<n> | EXTernal} for the DSO models
<source> ::= {CHANnel<n> | DIGital0,..,DIGital15} for the MSO models
<slope> ::= {POSitive | NEGative}
<n> ::= {1 | 2 | 3 | 4} for the four channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :TRIGger:SEQuence:EDGE<n> command defines the specified sequencer
edge resource according to the specified <source> and <slope>. To disable
an edge resource, set its <source> to NONE. In this case, <slope> has no
meaning.
Query Syntax
:TRIGger:SEQuence:EDGE{1 | 2}?
The :TRIGger:SEQuence:EDGE<n>? query returns the specified sequencer
edge resource setting. If the edge resource is disabled, the returned
<source> value is NONE. In this case, the <slope> is undefined.
Return Format
<source>, <slope><NL>
See Also
•
"Introduction to :TRIGger Commands"
•
•
•
•
Содержание InfiniiVision 7000A Series
Страница 1: ...Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide...
Страница 34: ...34 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 1 What s New...
Страница 44: ...44 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 2 Setting Up...
Страница 58: ...58 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 3 Getting Started...
Страница 652: ...652 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 5 Commands by Subsystem...
Страница 750: ...750 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 8 Error Messages...
Страница 784: ...784 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 10 Synchronizing Acquisitions...
Страница 810: ...810 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 11 More About Oscilloscope Commands...
Страница 922: ...922 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide Index...