534
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
5
Commands by Subsystem
:TRIGger:I2S:RANGe
Command Syntax
:TRIGger:I2S:RANGe <upper>,<lower>
<upper> ::= 32-bit integer in signed decimal, <nondecimal>,
or <string>
<lower> ::= 32-bit integer in signed decimal, <nondecimal>
or <string>
<nondecimal> ::= #Hnn...n where n ::= {0,..,9 | A,..,F}
for hexadecimal
<nondecimal> ::= #Bnn...n where n ::= {0 | 1} for binary
<string> ::= "0xnn...n" where n ::= {0,..,9 | A,..,F} for hexadecimal
The :TRIGger:I2S:RANGe command sets the upper and lower range
boundaries used by the INRange, OUTRange, INCReasing, and DECReasing
trigger conditions. You can enter the parameters in any order — the
smaller value becomes the <lower> and the larger value becomes the
<upper>.
Note that for INCReasing and DECReasing, the <upper> and <lower> values
correspond to the "Armed" and "Trigger" softkeys.
Query Syntax
:TRIGger:I2S:RANGe?
The :TRIGger:I2S:RANGe? query returns the currently set upper and lower
range boundaries.
Return Format
<upper>,<lower><NL>
<upper> ::= 32-bit integer in signed decimal, <nondecimal>,
or <string>
<lower> ::= 32-bit integer in signed decimal, <nondecimal>
or <string>
<nondecimal> ::= #Hnn...n where n ::= {0,..,9 | A,..,F}
for hexadecimal
<nondecimal> ::= #Bnn...n where n ::= {0 | 1} for binary
<string> ::= "0xnn...n" where n ::= {0,..,9 | A,..,F} for hexadecimal
See Also
•
"Introduction to :TRIGger Commands"
N O T E
The length of the <upper> and <lower> values is determined by the :TRIGger:I2S:RWIDth
and :TRIGger:I2S:TWIDth commands. When the receiver word size is less than the
transmitter word size, the length is equal to the receiver word size. When the receiver word
size is greater than the transmitter word size, the length is equal to the transmitter word
size.
Содержание InfiniiVision 7000A Series
Страница 1: ...Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide...
Страница 34: ...34 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 1 What s New...
Страница 44: ...44 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 2 Setting Up...
Страница 58: ...58 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 3 Getting Started...
Страница 652: ...652 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 5 Commands by Subsystem...
Страница 750: ...750 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 8 Error Messages...
Страница 784: ...784 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 10 Synchronizing Acquisitions...
Страница 810: ...810 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide 11 More About Oscilloscope Commands...
Страница 922: ...922 Agilent InfiniiVision 7000A Series Oscilloscopes Programmer s Guide Index...